Autostereoscopic 3D visualization and image processing system for neurosurgery

  • Tobias Meyer EMAIL logo , Julia Kuß , Falk Uhlemann , Stefan Wagner , Matthias Kirsch , Stephan B. Sobottka , Ralf Steinmeier , Gabriele Schackert and Ute Morgenstern

Abstract

A demonstrator system for planning neurosurgical procedures was developed based on commercial hardware and software. The system combines an easy-to-use environment for surgical planning with high-end visualization and the opportunity to analyze data sets for research purposes. The demonstrator system is based on the software AMIRA. Specific algorithms for segmentation, elastic registration, and visualization have been implemented and adapted to the clinical workflow. Modules from AMIRA and the image processing library Insight Segmentation and Registration Toolkit (ITK) can be combined to solve various image processing tasks. Customized modules tailored to specific clinical problems can easily be implemented using the AMIRA application programming interface and a self-developed framework for ITK filters. Visualization is done via autostereoscopic displays, which provide a 3D impression without viewing aids. A Spaceball device allows a comfortable, intuitive way of navigation in the data sets. Via an interface to a neurosurgical navigation system, the demonstrator system can be used intraoperatively. The precision, applicability, and benefit of the demonstrator system for planning of neurosurgical interventions and for neurosurgical research were successfully evaluated by neurosurgeons using phantom and patient data sets.


Corresponding author: Tobias Meyer, Klinik und Polyklinik für Neurochirurgie, Universitätsklinikum Carl Gustav Carus, Fetscherstrasse 74, 01307 Dresden, Germany, Phone: +49 351 458 3982, Fax: +49 351 458 4304

This work was financially supported by the Wilhelm-Sander-Stiftung.

References

[1] Abildgaard A, Witwit AK, Karlsen JS, Jacobsen EA, Tennøe B, Ringstad G, Due-Tønnessen P. An autostereoscopic 3D display can improve visualization of 3D models from intracranial MR angiography. Int J Comput Assist Radiol Surg 2010; 5: 549–554.10.1007/s11548-010-0509-5Search in Google Scholar

[2] Balan AGR, Traina AJM, Ribeiro MX, Marques PMA, Traina C. HEAD: the human encephalon automatic delimiter. In: Proceedings of the 20th IEEE Symposium on Computer-Based Medical Systems, IEEE CBMS 2007: 171–176.10.1109/CBMS.2007.54Search in Google Scholar

[3] Basser PJ. Inferring microstructural features and the physiological state of tissues from diffusion-weighted images. NMR Biomed 1995; 8: 333–344.10.1002/nbm.1940080707Search in Google Scholar

[4] Basser PJ, Pajevic S, Pierpaoli C, Duda J, Aldroubi A. In vivo fiber tractography using DT-MRI data. Magn Reson Med 2000; 44: 625–632.10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO;2-OSearch in Google Scholar

[5] Christopher LA, William A, Cohen-Gadol AA. Future directions in 3-dimensional imaging and neurosurgery: stereoscopy and autostereoscopy. Neurosurgery 2013; 72: 131–138.10.1227/NEU.0b013e318270d9c0Search in Google Scholar

[6] Cuadra MB, Cammoun L, Butz T, Cuisenaire O, Thiran J. Comparison and validation of tissue modelization and statistical classification methods in T1-weighted MR brain images. IEEE Trans Med Imaging 2005; 24: 1548–1565.10.1109/TMI.2005.857652Search in Google Scholar

[7] Gajanayake GMNR, Yapa RD, Hewawithana B. Comparison of standard image segmentation methods for segmentation of brain tumors from 2D MR images. In: Proceedings of the 4th International Conference on Industrial and Information Systems, ICIIS 2009, Peradeniya, IEEE 2009: 301–305.10.1109/ICIINFS.2009.5429848Search in Google Scholar

[8] Gering DT, Nabavi A, Kikinis R, et al. An integrated visualization system for surgical planning and guidance using image fusion and interventional imaging. Int Conf Med Image Comput Comput Assist Interv 1999; 2: 809–819.10.1007/10704282_88Search in Google Scholar

[9] Hartkens T, Hill DL, Castellano-Smith AD, et al. Measurement and analysis of brain deformation during neurosurgery. IEEE Trans Med Imaging 2003; 22: 82–92.10.1109/TMI.2002.806596Search in Google Scholar

[10] Kockro RA, Reisch R, Serra L, Goh LC, Lee E, Stadie AT. Image-guided neurosurgery with 3-dimensional multimodal imaging data on a stereoscopic monitor. Neurosurgery 2013; 72: 78–88.10.1227/NEU.0b013e3182739aaeSearch in Google Scholar

[11] König M, Spindler W, Rexilius J, Jomier J, Link F, Peitgen HO. Embedding VTK and ITK into a visual programming and rapid prototyping platform. SPIE Med Imaging 2006; 6141: 61412O.10.1117/12.652102Search in Google Scholar

[12] Kuß J, Wagner S, Meyer T, Kirsch M, Morgenstern U. Evaluation of an integrated tool for automated visualization of subdural electrodes. Proc World Congr Med Phys Biomed Eng 2009; 25: 1550–1553.10.1007/978-3-642-03882-2_411Search in Google Scholar

[13] Kuß J, Wagner S, Meyer T, et al. A head phantom prototype to verify subdural electrode localization tools in epilepsy surgery. Neuroimage 2011; 54: S256–S262.10.1016/j.neuroimage.2010.03.007Search in Google Scholar

[14] Le Bihan D, Mangin JF, Poupon C, et al. Diffusion tensor imaging: concepts and applications. J Magn Reson Imaging 2001; 13: 534–546.10.1002/jmri.1076Search in Google Scholar

[15] Nabavi A, Black PM, Gering DT, et al. Serial intraoperative magnetic resonance imaging of brain shift. Neurosurgery 2001; 48: 787–797.Search in Google Scholar

[16] Meyer T, Kitzler H, Sergeeva O, Krex D, Schackert G. Development of an interface to a neuro-navigation system for retrieving coordinates of tracked instruments. Dtsche Ges Comput Roboterassist Chir – CURAC 2006; 95. Available at: http://www.curac.org/vergangene_jahrestagungen/curac06/curac_freitag.php. Accessed on May 2013.Search in Google Scholar

[17] Meyer T, Sobottka SB, Kirsch M, et al. Intraoperative optical imaging of functional brain areas for improved image-guided surgery. Biomed Tech 2013; 58: 225–236.10.1515/bmt-2012-0072Search in Google Scholar

[18] Pluim JP, Maintz JB, Viergever MA. Mutual-information-based registration of medical images: a survey. IEEE Trans Med Imaging 2003; 22: 986–1004.10.1109/TMI.2003.815867Search in Google Scholar

[19] Sethian JA. Level set methods and fast marching methods. Cambridge, UK: Cambridge University Press 1999.10.1137/S0036144598347059Search in Google Scholar

[20] Shattuck DW, Leahy RM. BrainSuite: an automated cortical surface identification tool. Med Image Anal 2002; 6: 129–142.10.1016/S1361-8415(02)00054-3Search in Google Scholar

[21] Stadie AT, Kockro RA. Mono-stereo-autostereo: the evolution of 3-dimensional neurosurgical planning. Neurosurgery 2013; 72: 63–77.10.1227/NEU.0b013e318270d310Search in Google Scholar PubMed

[22] Stadie AT, Kockro RA, Reisch R, et al. Virtual reality system for planning minimally invasive neurosurgery. Technical note. J Neurosurg 2008; 108: 382–394.10.3171/JNS/2008/108/2/0382Search in Google Scholar PubMed

[23] Stieglitz LH, Fichtner J, Andres R, et al. The silent loss of neuronavigation accuracy: a systematic retrospective analysis of factors influencing the mismatch of frameless stereotactic systems in cranial neurosurgery. Neurosurgery 2013; 72: 796–807.10.1227/NEU.0b013e318287072dSearch in Google Scholar

[24] Wagner S. Adaption und Erweiterung des 3D-Demonstratorsystems für die Epilepsiechirurgie. Diplomarbeit, Technische Universität Dresden, Institut für Biomedizinische Technik 2009.Search in Google Scholar

[25] Wagner S, Kuss J, Meyer T, Kirsch M, Morgenstern U. An integrated tool for automated visualization of subdural electrodes in epilepsy surgery evaluation. Int J Comput Assist Radiol Surg 2009; 4: 609–616.10.1007/s11548-009-0378-ySearch in Google Scholar

[26] Westheimer G. Three-dimensional displays and stereo vision. Proc Biol Sci 2011; 278: 2241–2248.10.1098/rspb.2010.2777Search in Google Scholar

[27] Yang de L, Xu QW, Che XM, Wu JS, Sun B. Clinical evaluation and follow-up outcome of presurgical plan by Dextroscope: a prospective controlled study in patients with skull base tumors. Surg Neurol 2009; 72: 682–689.10.1016/j.surneu.2009.07.040Search in Google Scholar

[28] Yoo TS, Ackerman MJ, Lorensen WE, et al. Engineering and algorithm design for an image processing Api: a technical report on ITK – the Insight Toolkit. Stud Health Technol Inform 2002; 85: 586–592.Search in Google Scholar

[29] Zou KH, Warfield SK, Bharatha A, et al. Statistical validation of image segmentation quality based on a spatial overlap index. Acad Radiol 2004; 11: 178–189.10.1016/S1076-6332(03)00671-8Search in Google Scholar

Received: 2012-12-10
Accepted: 2013-5-15
Published Online: 2013-06-01
Published in Print: 2013-06-01

©2013 by Walter de Gruyter Berlin Boston

Downloaded on 29.3.2024 from https://www.degruyter.com/document/doi/10.1515/bmt-2012-0079/html
Scroll to top button