Retinal images benchmark for the detection of diabetic retinopathy and clinically significant macular edema (CSME)

  • Muhammad Noor-ul-huda EMAIL logo , Samabia Tehsin EMAIL logo , Sairam Ahmed , Fuad A.K. Niazi and Zeerish Murtaza

Abstract

Diabetes mellitus is an enduring disease related with significant morbidity and mortality. The main pathogenesis behind this disease is its numerous micro- and macrovascular complications. In developing countries, diabetic retinopathy (DR) is one of the major sources of vision impairment in working age population. DR has been classified into two categories: proliferative diabetic retinopathy (PDR) and non-proliferative diabetic retinopathy (NPDR). NPDR is further classified into mild, moderate and severe, while PDR is further classified into early PDR, high risk PDR and advanced diabetic eye disease. DR is a disease caused due to high blood glucose levels which result in vision loss or permanent blindness. High-level advancements in the field of bio-medical image processing have speeded up the automated process of disease diagnoses and analysis. Much research has been conducted and computerized systems have been designed to detect and analyze retinal diseases through image processing. Similarly, a number of algorithms have been designed to detect and grade DR by analyzing different symptoms including microaneurysms, soft exudates, hard exudates, cotton wool spots, fibrotic bands, neovascularization on disc (NVD), neovascularization elsewhere (NVE), hemorrhages and tractional bands. The visual examination of the retina is a vital test to diagnose DR-related complications. However, all the DR computer-aided diagnostic systems require a standard dataset for the estimation of their efficiency, performance and accuracy. This research presents a benchmark for the evaluation of computer-based DR diagnostic systems. The existing DR benchmarks are small in size and do not cover all the DR stages and categories. The dataset contains 1445 high-quality fundus photographs of retinal images, acquired over 2 years from the records of the patients who presented to the Department of Ophthalmology, Holy Family Hospital, Rawalpindi. This benchmark provides an evaluation platform for medical image analysis researchers. Furthermore, it provides evaluation data for all the stages of DR.

  1. Author Statement

  2. Research funding: Authors state no funding involved.

  3. Conflict of interest: Authors state no conflict of interest.

  4. Informed consent: Informed consent is not applicable.

  5. Ethical approval: The conducted research is not related to either human or animal use.

References

[1] Kulenovic I, Rasic S, Karcic S. Development of microvascular complications in type 1 diabetic patients 10 years follow-up. Bosn J Basic Med Sci 2006;6:47–50.10.17305/bjbms.2006.3171Search in Google Scholar PubMed

[2] Zhao C, Wang W, Xu D, Li H, Li M, Wang F. Insulin and risk of diabetic retinopathy in patients with type 2 diabetes mellitus: data from a meta-analysis of seven cohort studies. Diagn Pathol 2014;9:130.10.1186/1746-1596-9-130Search in Google Scholar PubMed

[3] Salti HI, Nasrallah MP, Taleb NM, Merheb M, Haddad S, El-Annan J, et al. Prevalence and determinants of retinopathy in a cohort of Lebanese type II diabetic patients. Can J Ophthalmol 2009;44:308–13.10.3129/i09-029Search in Google Scholar

[4] Scanlon PH, Aldington SJ, Stratton IM. Epidemiological issues in diabetic retinopathy. Middle East Afr J Ophthalmol 2013;20:293–300.10.4103/0974-9233.120007Search in Google Scholar PubMed

[5] Rema M, Premkumar S, Anitha B, Deepa R, Pradeepa R, Mohan V. Prevalence of diabetic retinopathy in urban India: the Chennai Urban Rural Epidemiology Study (CURES) eye study, I. Invest Ophthalmol Vis Sci 2005;46:2328–33.10.1167/iovs.05-0019Search in Google Scholar PubMed

[6] Early Treatment Diabetic Retinopathy Study Research Group. Early Treatment Diabetic Retinopathy Study design and baseline patient characteristics: ETDRS report number 7. Ophthalmology 1991;98:741–56.10.1016/S0161-6420(13)38009-9Search in Google Scholar PubMed

[7] Early Treatment Diabetic Retinopathy Study design and baseline patient characteristics: ETDRS report number 7. Ophthalmology 1991;98:742.10.1016/S0161-6420(13)38009-9Search in Google Scholar

[8] Grading diabetic retinopathy from stereoscopic color fundus photographs – an extension of the modified Airlie House classification: ETDRS report number 10. Ophthalmology 1991;98:786–806.10.1016/S0161-6420(13)38012-9Search in Google Scholar PubMed

[9] Hsu W, Pallawala PM, Lee ML, Eong KG. The role of domain knowledge in the detection of retinal hard exudates. Computer Vision and Pattern Recognition, 2001. CVPR 2001. Proceedings of the 2001 IEEE Computer Society Conference on 2001 (Vol. 2, pp. II–II). IEEE.10.1109/CVPR.2001.990967Search in Google Scholar

[10] Zimmerman J, Propes BD. Management of Cotton-wool Spots in Retina. Retinal Physician Management. 2013, https://www.retinalphysician.com/issues/2013/october-2013/management-of-cotton-wool-spots-in-retina.Search in Google Scholar

[11] Aldington SJ, Kohner EM, Meuer S, Klein R, Sjølie AK; EURODIAB IDDM Complications Study Group. Methodology for retinal photography and assessment of diabetic retinopathy: the EURODIAB IDDM complications study. Diabetologia 1995;38:437–44.10.1007/BF00410281Search in Google Scholar PubMed

[12] Cho H, Alwassia AA, Regiatieri CV, Zhang JY, Baumal C, Waheed N, et al. Retinal neovascularization secondary to proliferative diabetic retinopathy characterized by spectral domain optical coherence tomography. Retina (Philadelphia, PA) 2013;33:542–7.10.1097/IAE.0b013e3182753b6fSearch in Google Scholar PubMed PubMed Central

[13] Akram MU, Shahzad K, Shoaib AK. Identification and classification of micro aneurysms for early detection of diabetic retinopathy. Pattern Recogn 2013;46:107–16.10.1016/j.patcog.2012.07.002Search in Google Scholar

[14] Welikala RA, Dehmeshki J, Hoppe A, Tah V, Mann S, Williamson TH, et al. Automated detection of proliferative diabetic retinopathy using a modified line operator and dual classification. Comput Methods Programs Biomed 2014;114:247–61.10.1016/j.cmpb.2014.02.010Search in Google Scholar PubMed

[15] Amna W, Usman A, Shehzad K, Zahra W, Muazzam AK, Arslan S. Hybrid Features and Mediods Classification Based Robust Segmentation of Blood Vessels. New York: Springer Science Business Media; 2015.Search in Google Scholar

[16] Leontidis G. A new unified framework for the early detection of the progression to diabetic retinopathy from fundus images. Comput Biol Med 2017;90:98–115.10.1016/j.compbiomed.2017.09.008Search in Google Scholar PubMed

[17] Akram UM, Khan SA. Automated detection of dark and bright lesions in retinal images for early detection of diabetic retinopathy. J Med Syst 2012;36:3151. https://doi.org/10.1007/s10916-011-9802-2.10.1007/s10916-011-9802-2Search in Google Scholar PubMed

[18] Waheed A, Waheed Z, Usman Akram M, Shaukat A. Removal of false blood vessels using shape based features and image inpainting. Journal of Sensors 2015;2015, Article ID 839894, 13 pages.10.1155/2015/839894Search in Google Scholar

[19] Zhang X, Thibault G, Decencière E, Marcotegui B, Laÿ B, Danno R, et al. Exudate detection in color retinal images for mass screening of diabetic retinopathy. Med Image Anal 2014;18:1026–43.10.1016/j.media.2014.05.004Search in Google Scholar PubMed

[20] Sidra R, Shagufta. Computerized exudate detection in fundus images using statistical feature based fuzzy c-mean clustering. Int J Comput Dig Syst 2013;3:135–45.Search in Google Scholar

[21] Huiqi L, Chutatape O. A model-based approach for automated feature extraction in fundus images. In International Conference on Computer Vision (ICCV), 2003.Search in Google Scholar

[22] Waheed Z, Akram MU, Waheed A, Khan MA, Shaukat A, Ishaq M. Person identification using vascular and non-vascular retinal features. Comput Electr Eng 2016;53:359–71.10.1016/j.compeleceng.2016.03.010Search in Google Scholar

[23] Staal J, Abramoff MD, Niemeijer M, Viergever MA, van Ginneken B. Ridge based vessel segmentation in color images of the retina. IEEE Trans Med Imaging 2004;23:501–9.10.1109/TMI.2004.825627Search in Google Scholar PubMed

[24] Structured Analysis of Retina (STARE). http://cecas.clemson.edu/~ahoover/stare/.Search in Google Scholar

[25] Kauppi T, Kalesnykiene V, Kamarainen J-K, Lensu L, Sorri I, Uusitalo H, et al. DIARETDB0: evaluation database and methodology for diabetic retinopathy algorithms. Available online at: http://www.it.lut.fi/project/imageret/diaretdb0.Search in Google Scholar

[26] Kauppi T, Kalesnykiene V, Kamarainen J-K, Lensu L, Sorri I, Raninen A, et al. DIARETDB1 diabetic retinopathy database and evaluation protocol. In Proc of the 11th Conf. on Medical Image Understanding and Analysis (Aberystwyth, Wales, 2007). http://www2.it.lut.fi/project/imageret/diaretdb1.10.5244/C.21.15Search in Google Scholar

[27] IMAGERET Optimal Detection and Decision-Support Diagnosis of Diabetic Retinopathy. http://www2.it.lut.fi/project/imageret.Search in Google Scholar

[28] Budai A, Bock R, Maier A, Hornegger J, Michelson G. Robust vessel segmentation in fundus images. Int J Biomed Imaging 2013;2013. Available online at: https://www5.cs.fau.de/research/data/fundus-images.10.1155/2013/154860Search in Google Scholar PubMed PubMed Central

[29] Retinal Identification Database “RIDB”. Available online at: http://biomisa.org/ridb ().Search in Google Scholar

[30] “Methods to evaluate segmentation and indexing techniques in the field of retinal ophthalmology (MESSIDOR)”. Available Online at http://messidor.crihan.fr/index-en.php.Search in Google Scholar

Received: 2018-03-06
Accepted: 2018-06-15
Published Online: 2018-07-28
Published in Print: 2019-05-27

©2019 Walter de Gruyter GmbH, Berlin/Boston

Downloaded on 29.3.2024 from https://www.degruyter.com/document/doi/10.1515/bmt-2018-0098/html
Scroll to top button