Jump to ContentJump to Main Navigation
Show Summary Details
More options …

Biomedical Engineering / Biomedizinische Technik

Joint Journal of the German Society for Biomedical Engineering in VDE and the Austrian and Swiss Societies for Biomedical Engineering and the German Society of Biomaterials

Editor-in-Chief: Dössel, Olaf

Editorial Board: Augat, Peter / Habibović, Pamela / Haueisen, Jens / Jahnen-Dechent, Wilhelm / Jockenhoevel, Stefan / Knaup-Gregori, Petra / Lenarz, Thomas / Leonhardt, Steffen / Plank, Gernot / Radermacher, Klaus M. / Schkommodau, Erik / Stieglitz, Thomas / Boenick, Ulrich / Jaramaz, Branislav / Kraft, Marc / Lenthe, Harry / Lo, Benny / Mainardi, Luca / Micera, Silvestro / Penzel, Thomas / Robitzki, Andrea A. / Schaeffter, Tobias / Snedeker, Jess G. / Sörnmo, Leif / Sugano, Nobuhiko / Werner, Jürgen /

6 Issues per year


IMPACT FACTOR 2017: 1.096
5-year IMPACT FACTOR: 1.492

CiteScore 2017: 0.48

SCImago Journal Rank (SJR) 2017: 0.202
Source Normalized Impact per Paper (SNIP) 2017: 0.356

Online
ISSN
1862-278X
See all formats and pricing
More options …
Volume 63, Issue 3

Issues

Volume 57 (2012)

Hybrid textile heart valve prosthesis: preliminary in vitro evaluation

Antoine Vaesken / Christian Pidancier / Nabil Chakfe
  • Service de Chirurgie Vasculaire – GEPROVAS, Hôpitaux Universitaires de Strasbourg, 67000 Strasbourg, France
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Frederic Heim
  • Corresponding author
  • Laboratoire de Physique et Mécanique Textiles EA 4365, ENSISA, Mulhouse, France, Phone: +33 6 79 77 02 32, Fax: +33 3 89 33 63 39
  • Email
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2016-09-22 | DOI: https://doi.org/10.1515/bmt-2016-0083

Abstract

Transcatheter aortic valve implantation (TAVI) is nowadays a popular alternative technique to surgical valve replacement for critical patients. Biological valve tissue has been used in these devices for over a decade now with over 100,000 implantations. However, material degradations due to crimping for catheter insertion purpose have been reported, and with only 6-year follow-up, no information is available about the long-term durability of biological tissue. Moreover, expensive biological tissue harvesting and chemical treatment procedures tend to promote the development of synthetic valve leaflet materials. Textile polyester (PET) material is characterized by outstanding folding and strength properties combined with proven biocompatibility and could therefore be considered as a candidate to replace biological valve leaflets in TAVI devices. Nevertheless, the material should be preferentially partly elastic in order to limit water hammer effects at valve closing time and prevent exaggerated stress from occurring into the stent and the valve. The purpose of the present work is to study in vitro the mechanical as well as the hydrodynamic behavior of a hybrid elastic textile valve device combining non-deformable PET yarn and elastic polyurethane (PU) yarn. The hybrid valve properties are compared with those of a non-elastic textile valve. Testing results show improved hydrodynamic properties with the elastic construction. However, under fatigue conditions, the interaction between PU and PET yarns tends to limit the valve durability.

Keywords: composite; heart valve; hybrid; textile; transcatheter; transcatheter aortic valve implantation (TAVI)

References

  • [1]

    Alavi H, Groves E, Kheradvar A. The effects of transcatheter valve crimping on pericardial leaflets. Ann Thorac Surg 2014; 97: 1260–1266.Google Scholar

  • [2]

    Amoroso NJ, D’Amore A, Hong Y, Rivera CP, Sacks MS, Wagner WR. Microstructural manipulation of electrospun scaffolds for specific bending stiffness for heart valve tissue engineering. Acta Biomater 2012; 8: 4268–4277.Google Scholar

  • [3]

    Bernacca GM, Mackay TG, Wilkinson R, Wheatley DJ. Polyurethane heart valves: fatigue failure, calcification, and polyurethane structure. J Biomed Mater Res 1997; 34: 371–379.Google Scholar

  • [4]

    Bezuidenhout D, Williams DF, Zilla P. Polymeric heart valves for surgical implantation, catheter-based technologies and heart assist devices. Biomaterials 2005; 36: 2–25.Google Scholar

  • [5]

    Braunwald NS, Cooper T, Morrow AG. Complete replacement of the mitral valve. Successful clinical application of a flexible polyurethane prosthesis. J Thorac Cardiovasc Surg 1960; 40: 1–11.Google Scholar

  • [6]

    Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis, first human case description. Circulation 2002; 106: 3006–3008.Google Scholar

  • [7]

    Daebritz SH, Fausten B, Hermanns B, et al. New flexible polymeric heart valve prostheses for the mitral and aortic positions. Heart Surg Forum 2004; 7: E525–E532.Google Scholar

  • [8]

    Davidson MJ, White JK, Baim DS. Percutaneous therapies for valvular heart disease. Cardiovasc Pathol 2006; 15: 123–129.Google Scholar

  • [9]

    Haller N. Noninvasive analysis of synthetic and decellularized scaffolds for heart valve tissue engineering. ASAIO J 2013; 59: 169–177.Google Scholar

  • [10]

    Khoffi F, Heim F. Mechanical degradation of biological heart valve tissue induced by low diameter crimping: an early assessment. J Mech Behav Biomed Mater 2015; 44: 71–5.Google Scholar

  • [11]

    Khoffi F, Heim F, Chakfe N, Lee JT. Transcatheter fiber heart valve: effect of crimping on material performances. J Biomed Mater Res B Appl Biomater 2015; 103: 1488–1497.Google Scholar

  • [12]

    Kiefer P, Gruenwald F, Kempfert J, et al. Crimping may affect the durability of transcatheter valves: an experimental analysis. Ann Thorac Surg 2011; 92: 155–160.Google Scholar

  • [13]

    Kucinska-Lipka J, Gubanska I, Janik H, Sienkiewicz M. Fabrication of polyurethane and polyurethane based composite fibres by the electrospinning technique for soft tissue engineering of cardiovascular system. Mater Sci Eng C Mater Biol Appl 2015; 46: 166–176.Google Scholar

  • [14]

    Roe BB, Kelly Jr PB, Myers JL, Moore DW. Tricuspid leaflet aortic valve prosthesis. Circulation 1966; 33(4 Suppl): I124–I130.Google Scholar

  • [15]

    Vaesken A, Heim F. Textile heart valve: fabric construction parameter and in vivo results. The Fiber Society’s Spring Conference 2015, Shanghai, China; 05/2015Google Scholar

  • [16]

    Vaesken A, Heim F, Chakfe N. Fiber heart valve prosthesis: influence of the fabric construction parameters on the valve fatigue performances. J Mech Behav Biomed Mater 2014; 40: 69–74.Google Scholar

  • [17]

    Zadeh PB, Corbett SC, Nayeb-Hashemi H. In vitro calcification study of polyurethane heart valves. Mater Sci Eng C Mater Biol Appl 2014; 35: 335–340.Google Scholar

  • [18]

    Zegdi R, Ciobotaru V, Noghin M, et al. Is it reasonable to treat all calcified stenotic aortic valves with a valved stent. J Am Coll Cardiol 2008; 51: 579–584.Google Scholar

About the article

Received: 2016-04-05

Accepted: 2016-08-19

Published Online: 2016-09-22

Published in Print: 2018-06-27


Author Statement

Research funding: Authors state no funding involved.

Conflict of interest: Authors state no conflict of interest.

Informed consent: Informed consent is not applicable.

Ethical approval: Ethical approval is not applicable.


Citation Information: Biomedical Engineering / Biomedizinische Technik, Volume 63, Issue 3, Pages 333–339, ISSN (Online) 1862-278X, ISSN (Print) 0013-5585, DOI: https://doi.org/10.1515/bmt-2016-0083.

Export Citation

©2018 Walter de Gruyter GmbH, Berlin/Boston.Get Permission

Comments (0)

Please log in or register to comment.
Log in