Editorial Board Member: Augat, Peter / Haueisen, Jens / Jockenhoevel, Stefan / Lenarz, Thomas / Leonhardt, Steffen / Plank, Gernot / Radermacher, Klaus M. / Schkommodau, Erik / Schmitz, Georg / Stieglitz, Thomas / Witte, Herbert / Boenick, Ulrich / Jaramaz, Branislav / Kraft, Marc / Lenthe, Harry / Lo, Benny / Mainardi, Luca / Micera, Silvestro / Penzel, Thomas / Robitzki, Andrea A. / Schaeffter, Tobias / Snedeker, Jess G. / Sörnmo, Leif / Sugano, Nobuhiko / Werner, Jürgen / Wintermantel, Erich /

6 Issues per year


IMPACT FACTOR increased in 2015: 1.650

Online
ISSN
1862-278X
See all formats and pricing
Ahead of print

Issues

Volume 57 (2012)

Hybrid textile heart valve prosthesis: preliminary in vitro evaluation

Antoine Vaesken
  • Laboratoire de Physique et Mécanique Textiles EA 4365, ENSISA, Mulhouse, France
/ Christian Pidancier
  • Laboratoire de Physique et Mécanique Textiles EA 4365, ENSISA, Mulhouse, France
/ Nabil Chakfe
  • Service de Chirurgie Vasculaire – GEPROVAS, Hôpitaux Universitaires de Strasbourg, 67000 Strasbourg, France
/ Frederic Heim
  • Corresponding author
  • Laboratoire de Physique et Mécanique Textiles EA 4365, ENSISA, Mulhouse, France, Phone: +33 6 79 77 02 32, Fax: +33 3 89 33 63 39
  • Email:
Published Online: 2016-09-22 | DOI: https://doi.org/10.1515/bmt-2016-0083

Abstract

Transcatheter aortic valve implantation (TAVI) is nowadays a popular alternative technique to surgical valve replacement for critical patients. Biological valve tissue has been used in these devices for over a decade now with over 100,000 implantations. However, material degradations due to crimping for catheter insertion purpose have been reported, and with only 6-year follow-up, no information is available about the long-term durability of biological tissue. Moreover, expensive biological tissue harvesting and chemical treatment procedures tend to promote the development of synthetic valve leaflet materials. Textile polyester (PET) material is characterized by outstanding folding and strength properties combined with proven biocompatibility and could therefore be considered as a candidate to replace biological valve leaflets in TAVI devices. Nevertheless, the material should be preferentially partly elastic in order to limit water hammer effects at valve closing time and prevent exaggerated stress from occurring into the stent and the valve. The purpose of the present work is to study in vitro the mechanical as well as the hydrodynamic behavior of a hybrid elastic textile valve device combining non-deformable PET yarn and elastic polyurethane (PU) yarn. The hybrid valve properties are compared with those of a non-elastic textile valve. Testing results show improved hydrodynamic properties with the elastic construction. However, under fatigue conditions, the interaction between PU and PET yarns tends to limit the valve durability.

Keywords: composite; heart valve; hybrid; textile; transcatheter; transcatheter aortic valve implantation (TAVI)

References

  • [1]

    Alavi H, Groves E, Kheradvar A. The effects of transcatheter valve crimping on pericardial leaflets. Ann Thorac Surg 2014; 97: 1260–1266.

  • [2]

    Amoroso NJ, D’Amore A, Hong Y, Rivera CP, Sacks MS, Wagner WR. Microstructural manipulation of electrospun scaffolds for specific bending stiffness for heart valve tissue engineering. Acta Biomater 2012; 8: 4268–4277.

  • [3]

    Bernacca GM, Mackay TG, Wilkinson R, Wheatley DJ. Polyurethane heart valves: fatigue failure, calcification, and polyurethane structure. J Biomed Mater Res 1997; 34: 371–379.

  • [4]

    Bezuidenhout D, Williams DF, Zilla P. Polymeric heart valves for surgical implantation, catheter-based technologies and heart assist devices. Biomaterials 2005; 36: 2–25.

  • [5]

    Braunwald NS, Cooper T, Morrow AG. Complete replacement of the mitral valve. Successful clinical application of a flexible polyurethane prosthesis. J Thorac Cardiovasc Surg 1960; 40: 1–11.

  • [6]

    Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis, first human case description. Circulation 2002; 106: 3006–3008.

  • [7]

    Daebritz SH, Fausten B, Hermanns B, et al. New flexible polymeric heart valve prostheses for the mitral and aortic positions. Heart Surg Forum 2004; 7: E525–E532. [Crossref]

  • [8]

    Davidson MJ, White JK, Baim DS. Percutaneous therapies for valvular heart disease. Cardiovasc Pathol 2006; 15: 123–129.

  • [9]

    Haller N. Noninvasive analysis of synthetic and decellularized scaffolds for heart valve tissue engineering. ASAIO J 2013; 59: 169–177.

  • [10]

    Khoffi F, Heim F. Mechanical degradation of biological heart valve tissue induced by low diameter crimping: an early assessment. J Mech Behav Biomed Mater 2015; 44: 71–5.

  • [11]

    Khoffi F, Heim F, Chakfe N, Lee JT. Transcatheter fiber heart valve: effect of crimping on material performances. J Biomed Mater Res B Appl Biomater 2015; 103: 1488–1497.

  • [12]

    Kiefer P, Gruenwald F, Kempfert J, et al. Crimping may affect the durability of transcatheter valves: an experimental analysis. Ann Thorac Surg 2011; 92: 155–160.

  • [13]

    Kucinska-Lipka J, Gubanska I, Janik H, Sienkiewicz M. Fabrication of polyurethane and polyurethane based composite fibres by the electrospinning technique for soft tissue engineering of cardiovascular system. Mater Sci Eng C Mater Biol Appl 2015; 46: 166–176.

  • [14]

    Roe BB, Kelly Jr PB, Myers JL, Moore DW. Tricuspid leaflet aortic valve prosthesis. Circulation 1966; 33(4 Suppl): I124–I130.

  • [15]

    Vaesken A, Heim F. Textile heart valve: fabric construction parameter and in vivo results. The Fiber Society’s Spring Conference 2015, Shanghai, China; 05/2015

  • [16]

    Vaesken A, Heim F, Chakfe N. Fiber heart valve prosthesis: influence of the fabric construction parameters on the valve fatigue performances. J Mech Behav Biomed Mater 2014; 40: 69–74.

  • [17]

    Zadeh PB, Corbett SC, Nayeb-Hashemi H. In vitro calcification study of polyurethane heart valves. Mater Sci Eng C Mater Biol Appl 2014; 35: 335–340.

  • [18]

    Zegdi R, Ciobotaru V, Noghin M, et al. Is it reasonable to treat all calcified stenotic aortic valves with a valved stent. J Am Coll Cardiol 2008; 51: 579–584.