Jump to ContentJump to Main Navigation
Show Summary Details

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM)

Editor-in-Chief: Plebani, Mario

Ed. by Gillery, Philippe / Lackner, Karl J. / Lippi, Giuseppe / Melichar, Bohuslav / Payne, Deborah A. / Schlattmann, Peter / Tate, Jillian R.

12 Issues per year


IMPACT FACTOR increased in 2015: 3.017
Rank 5 out of 30 in category Medical Laboratory Technology in the 2014 Thomson Reuters Journal Citation Report/Science Edition

SCImago Journal Rank (SJR) 2015: 0.873
Source Normalized Impact per Paper (SNIP) 2015: 0.982
Impact per Publication (IPP) 2015: 2.238

Online
ISSN
1437-4331
See all formats and pricing
Volume 38, Issue 4 (Apr 2000)

Issues

Comparison of the Abbott IMx® and a High-Performance Liquid Chromatography Method for Measuring Total Plasma Homocysteine

Francisco Blanco-Vaca / Rosa Arcelús / Francesc González-Sastre / Jordi Ordóñez-Llanos / Josep M. Queraltó-Compañó
Published Online: 2005-06-01 | DOI: https://doi.org/10.1515/CCLM.2000.047

Abstract

The determination of the total concentration of plasma homocysteine is of interest in a variety of clinical circumstances, especially, in the evaluation of the risk of cardiovascular disease. However, most of the methods available to date, many of them chromatographic, are not well suited for the majority of clinical laboratories. Several automated methods are now or will be, shortly, commercially available. We have compared one of them, the fluorescence polarization immunoassay (FPIA) adapted to the IMx® analyzer (Abbott Laboratories), with the high-performance liquid chromatography (HPLC) method with fluorescent detection currently used in our laboratory. The results show that the FPIA-IMx® method is less imprecise and slightly more sensitive than the HPLC. The comparison of 67 clinical plasma specimens indicated that there is a proportional error disagreement between FPIA-IMx® and HPLC (FPIA=1.19 HPLC + 0.92; confidence region for slope and y-intercept were, respectively, from 1.06 to 1.31 and from−0.06 to 2.32). The nature of this error is not explained by the experiments performed to study the inaccuracy of both methods, which included the investigation of dilution parallelism, analytical recovery and cross-reactivity. The different results of homocysteine concentration obtained with FPIA-IMx® and HPLC must be taken into account when a change of methodology is under consideration.

About the article

Published Online: 2005-06-01

Published in Print: 2000-04-30


Citation Information: Clinical Chemistry and Laboratory Medicine, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/CCLM.2000.047. Export Citation

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
L. Calpe-Berdiel, J.C. Escolà-Gil, V. Ribas, R. Arcelus, and F. Blanco-Vaca
Clínica e Investigación en Arteriosclerosis, 2004, Volume 16, Number 5, Page 192
[2]
F. Blanco Vaca
Clínica e Investigación en Arteriosclerosis, 2003, Volume 15, Number 2, Page 69
[3]
V. Bianchi, A. Lanati, F. Martino, S. Piccinini, A. Pinca, G. Sida, M. Demicheli, C. Arfini, and M. Vidali
Clinica Chimica Acta, 2012, Volume 413, Number 21-22, Page 1768
[4]
H.Robert Superko and Harvey S Hecht
The American Journal of Cardiology, 2001, Volume 88, Number 3, Page 260
[5]
Joan Llevadot, Francisco Blanco Vaca, and Francesc González Sastre
Medicina Clínica, 2005, Volume 124, Number 14, Page 544
[6]
Sezer Calişkan, Filiz Kuralay, and Banu Önvural
Clinica Chimica Acta, 2001, Volume 309, Number 1, Page 53
[7]
A. Pérez, J.M. Cubero, N. Sucunza, E. Ortega, R. Arcelús, J. Rodriguez-Espinosa, J. Ordoñez-Llanos, and F. Blanco-Vaca
Metabolism, 2004, Volume 53, Number 11, Page 1512
[8]
Juan Carlos Souto, Francisco Blanco-Vaca, José Manuel Soria, Alfonso Buil, Laura Almasy, Jordi Ordoñez-Llanos, Jesús Mª Martín-Campos, Mark Lathrop, William Stone, John Blangero, and Jordi Fontcuberta
The American Journal of Human Genetics, 2005, Volume 76, Number 6, Page 925
[9]
Stéphanie Badiou, Nathalie Terrier, Isabelle Jaussent, Estelle Naudin, François Maurice, Anne-Marie Dupuy, Hélène Leray-Moragues, Jean-Pierre Rivory, Cécile Delcourt, Bernard Canaud, and Jean-Paul Cristol
Clinical Chemical Laboratory Medicine, 2006, Volume 44, Number 8
[10]
M. MARIETTA, L. SIMONI, P. PEDRAZZI, L. FACCHINI, R. D’AMICO, and F. FACCHINETTI
International Journal of Laboratory Hematology, 2009, Volume 31, Number 2, Page 227
[11]
M. MARIETTA, L. SIMONI, P. PEDRAZZI, L. FACCHINI, R. D’AMICO, and F. FACCHINETTI
International Journal of Laboratory Hematology, 2007, Volume 0, Number 0, Page 071115151007002
[12]
H. Robert Superko, Enas A. Enas, Purushotham Kotha, Naras K. Bhat, and Brenda Garrett
Preventive Cardiology, 2005, Volume 8, Number 2, Page 81
[13]
Robert Fritsche-Polanz, MD, Andrea Huber, Wolfgang Hagen, MD, Alexandra Feix, MD, Anna-Christine Hauser, MD, Gere Sunder-Plassmann, MD, Christian Bieglmayer, PhD, and Manuela FÖdinger, MD
Laboratory Medicine, 2003, Volume 34, Number 7, Page 538
[14]
M. Marietta, F. Facchinetti, L. Sgarbi, L. Simoni, M. Bertesi, G. Torelli, and A. Volpe
Journal of Thrombosis and Haemostasis, 2003, Volume 1, Number 12, Page 2536
[15]
Yew-Ming Kuan, Anthony E. Dear, and Michael J. Grigg
ANZ Journal of Surgery, 2002, Volume 72, Number 9, Page 668

Comments (0)

Please log in or register to comment.
Log in