Jump to ContentJump to Main Navigation
Show Summary Details
In This Section

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM)

Editor-in-Chief: Plebani, Mario

Ed. by Gillery, Philippe / Lackner, Karl J. / Lippi, Giuseppe / Melichar, Bohuslav / Payne, Deborah A. / Schlattmann, Peter / Tate, Jillian R.

12 Issues per year


IMPACT FACTOR 2016: 3.432

CiteScore 2016: 2.21

SCImago Journal Rank (SJR) 2015: 0.873
Source Normalized Impact per Paper (SNIP) 2015: 0.982

Online
ISSN
1437-4331
See all formats and pricing
In This Section
Volume 42, Issue 1 (Feb 2004)

Issues

Analytical goals for coagulation tests based on biological variation

Yui Wada / Masako Kurihara / Mitsuko Toyofuku / Minako Kawamura / Hiroko Iida / Yuzou Kayamori / Sachiko Kinoshita / Naotaka Hamasaki
Published Online: 2005-06-01 | DOI: https://doi.org/10.1515/CCLM.2004.015

Abstract

Allowable imprecision and bias reference limits for laboratory data can be calculated based on measurements of biological variation. Although biological variation of clinical chemical data has been reported from many laboratories, there have been few reports of biological variation in coagulation tests. In this study, we calculated the biological variation of 13 coagulation tests in the clinical laboratory of Kyushu University Hospital and determined allowable imprecision and bias limits of variation. The participating subjects were 17 healthy individuals: three males and two females in their 20s, two males and two females in their 30s, one male and four females in their 40s, and two males and one female in their 50s. Monthly measurements were performed before breakfast 12 times from June 2001 to May 2002 and allowable imprecision and bias limits were calculated. Taken together with coefficient of variation of control plasma used in daily laboratory work at the hospital, the allowable imprecision limits of intra-laboratory variation determined in this study appear to be in attainable ranges.

About the article

Published Online: 2005-06-01

Published in Print: 2004-02-16



Citation Information: Clinical Chemistry and Laboratory Medicine, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/CCLM.2004.015. Export Citation

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
Armelle de Laforcade, Robert Goggs, and Bo Wiinberg
Journal of Veterinary Emergency and Critical Care, 2014, Volume 24, Number 1, Page 37
[2]
Allison L. O'Kell, David C. Grant, David L. Panciera, Gregory C. Troy, and Nicole M. Weinstein
American Journal of Veterinary Research, 2012, Volume 73, Number 10, Page 1569
[3]
Bo Wiinberg, Asger Lundorff Jensen, Mads Kjelgaard-Hansen, Rasmus Rojkjaer, Pär I. Johansson, Laust Peter Gade, Dorte Xenia Gram, and Annemarie T. Kristensen
The Veterinary Journal, 2007, Volume 174, Number 1, Page 62

Comments (0)

Please log in or register to comment.
Log in