External Quality Assessment in The Netherlands: time to introduce commutable survey specimens. Lessons from the Dutch “Calibration 2000” project

Henk Baadenhuijsen
  • Dutch Foundation for Quality Assessment in Clinical Laboratories, University Hospital Nijmegen, Nijmegen, The Netherlands
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Aldy Kuypers
  • Dutch Foundation for Quality Assessment in Clinical Laboratories, University Hospital Nijmegen, Nijmegen, The Netherlands
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Cas Weykamp / Christa Cobbaert / Rob Jansen
Published Online: 2014-06-05 | DOI: https://doi.org/10.1515/CCLM.2005.052

Abstract

The performance of suitable secondary reference material for the use of trueness control of six routinely measured clinical enzymes in the Dutch External Quality Assessment (EQA) scheme is described. The reference material of choice was selected using the split-patient-sample between-field method (twin study) design as described in an earlier study of the Calibration 2000 project in The Netherlands. This material, which was proven to be commutable for all wet chemistry systems, was implemented as the national enzyme calibrator. It consisted of a cryo-protected lyophilised serum with additions of recombinant human enzymes. Various batches of the frozen version of this material without cryo-protection additive, called native EQA samples, were used in the general EQA scheme for performance evaluation. The results of Calibration 2000 calibrated and non-Calibration 2000 calibrated laboratories were compared for both the regular (spiked with non-human enzymes) and native EQA samples in terms of precision and bias with established reference method values for the native samples. The regular samples showed mean between-laboratory CV ranges for all six enzymes involved (low–high) of 5.5–10.3% for the non-calibrated users vs. 4.6–10.8% for the calibrated users. For the native samples these respective ranges were 5.2–9.9% vs. 2.2–4.9%. Without exception, the group of Calibration 2000 calibrated users showed the lowest bias against the reference method values. Regular EQA samples (spiked with non-human enzymes) showed poorer performance than native samples and are not suitable for accuracy assessment purposes, the main aim of EQA schemes. Native samples that are commutable should be used for trueness control in current EQA schemes.

Keywords: calibration; commutability; enzyme activity; External Quality Assessment; reference materials

References

  • 1

    The Committee on Enzymes of the Scandinavian Society for Clinical Chemistry and Clinical Physiology. Recommended methods for the determination of four enzymes in blood. Scand J Clin Lab Invest 1974;33:287–306. Google Scholar

  • 3

    The Committee on Enzymes of the Scandinavian Society for Clinical Chemistry and Clinical Physiology. Recommended methods for the determination of γ-glutamyltransferase in blood. Scand J Clin Lab Invest 1976;36:119–25. Google Scholar

  • 3

    The Committee on Enzymes of the Scandinavian Society for Clinical Chemistry and Clinical Physiology. Recommended methods for the determination of creatine kinase in blood modified by the inclusion of EDTA. Scand J Clin Lab Invest 1979;39:1–5. Google Scholar

  • 4

    Bergmeyer HU, Hørder M, Rej R. Approved recommendation (1985) on IFCC methods for the measurement of catalytic concentrations of enzymes. Part 2. IFCC method for aspartate aminotransferase (L-aspartate:2-oxoglutarate aminotransferase, EC 2.6.1.1). J Clin Chem Clin Biochem 1986; 24: 497–510. Google Scholar

  • 5

    Bergmeyer HU, Hørder M, Rej R. Approved recommendation (1985) on IFCC methods for the measurement of catalytic concentrations of enzymes. Part 3. IFCC method for alanine aminotransferase (L-alanine:2-oxoglutarate aminotransferase, EC 2.6.1.2). J Clin Chem Clin Biochem 1986; 24: 481–95. Google Scholar

  • 6

    Shaw LM, Strømme JH, London JL, Theodorsen L. IFCC methods for the measurement of catalytic concentrations of enzymes. Part 4. IFCC method for γ-glutamyltrans-ferase [(γ-glutamyl)-peptide: amino acid γ-glutamyltransferase, EC 2.3.2.2]. J Clin Chem Clin Biochem 1983; 21: 633–46. Google Scholar

  • 7

    Hørder M, Elser RC, Gerhardt W, Mathieu M, Sampson EJ. Approved recommendation (1985) on IFCC methods for the measurement of catalytic concentrations of enzymes. Part 7. IFCC method for creatine kinase (ATP:creatinine N-phosphotransferase, EC 2.7.3.2). J Clin Chem Clin Biochem 1991; 29: 435–56. Google Scholar

  • 8

    Bais R, Philcox M. Approved recommendation on IFCC methods for the measurement of catalytic concentrations of enzymes. Part 8. IFCC method for lactate dehydrogenase (L-lactate:NAD + oxidoreductase, EC 1.1.1.27). Eur J Clin Chem Clin Biochem 1994; 32: 639–55. Google Scholar

  • 9

    Lorentz K. Approved recommendation on IFCC methods for the measurement of catalytic concentrations of enzymes. Part 9. IFCC method for α-amylase (1,4-α-D-glucan-4-glucanohydrolase, EC 3.2.1.1). Clin Chem Lab Med 1998; 36: 185–203. CrossrefGoogle Scholar

  • 10

    Grannis GF, Massion CG, Batsakis JG. The 1978 College of American Pathologists survey of analysis of five serum enzymes by 450 laboratories. Am J Clin Pathol 1979; 72: 285–98. Google Scholar

  • 11

    Jansen RT, Jansen AP. Standards versus standardized methods in enzyme assay. Ann Clin Biochem 1983; 20: 52–9. CrossrefGoogle Scholar

  • 12

    Müller MM. Implementation of reference systems in laboratory medicine. Clin Chem 2000; 46: 1907–9. Google Scholar

  • 13

    Panteghini M, Ceriotti F, Schumann G, Siekmann L. Establishing a reference system in clinical enzymology. Clin Chem Lab Med 2001; 39: 795–800. CrossrefGoogle Scholar

  • 14

    EU Lex. Directive 98/79 EC on in vitro medical devices. Off J L 1998;331:1–37. Google Scholar

  • 15

    Lessinger JM, Férard G, Grafmeyer D, Labbé D, Maire I, Schiele F, et al. Usefulness of reference materials in calibration of enzyme activities. Eur J Clin Chem Clin Biochem 1995; 33: 859–64. Google Scholar

  • 16

    Franzini C, Ceriotti F. Impact of reference materials on accuracy in clinical chemistry. Clin Biochem 1998; 31: 449–57. CrossrefGoogle Scholar

  • 17

    Baadenhuijsen H, Steigstra H, Cobbaert C, Kuypers A, Weykamp C, Jansen R. Commutability assessment of potential reference material using a split-patient-sample between-field methods (twin-study) design: study within the framework of the Dutch project “Calibration 2000”. Clin Chem 2002; 48: 1521–25. Google Scholar

  • 18

    Aoki R, Misaka H, Ueda S. Enzyme reference materials from recombinant cells of human enzyme and human tissue sources. In: Martin SM, Halloran SP, editors. Proceedings of the XVI International Congress of Clinical Chemistry, 8–12 July 1996, London. London: Association of Clinical Biochemists, 1996:50. Google Scholar

  • 19

    Baadenhuijsen H, Demacker PN, Hessels M, Boerma GJ, Penders TJ, Weykamp C, et al. Testing the accuracy of total cholesterol assays in an external quality-control program: effect of adding sucrose to lyophilized control sera compared with use of fresh or frozen serum. Clin Chem 1995; 41: 724–30. Google Scholar

  • 20

    Steigstra H, Jansen RTP, Baadenhuijsen H. Combi scheme: new combined internal/external quality assessment scheme in The Netherlands. Clin Chem 1991; 37: 1196–204. Google Scholar

  • 21

    Ricos C, Alvarez V, Cava F, Garcia-Lario JV, Hernandez A, Jimenez CV, et al. Current databases on biologic variation: pros, cons and progress. Scand J Clin Lab Invest 1999; 59: 491–500. CrossrefGoogle Scholar

  • 22

    National Committee for Clinical Laboratory Standards. Evaluation of matrix effects; approved guideline. NCCLS document EP14A. Wayne, PA: NCCLS, 1999. Google Scholar

  • 23

    Scharnhorst V, Apperloo J, Baadenhuijsen H, Vader HL. Multicenter evaluation of the commutability of a potential reference material for harmonization of enzyme activities. Clin Chem Lab Med 2004; 4: 1401–7. Google Scholar

  • 24

    Ross JW, Miller WG, Myers GL, Praestguard J. The accuracy of laboratory measurements in clinical chemistry. Arch Pathol Lab Med 1998; 122: 587–608. Google Scholar

  • 25

    Thienpont LM, Stöckl D, Friedecky B, Kratochvila J, Budina M. Trueness verification in European external quality assessment schemes: time to care about the quality of samples. Scand J Clin Lab Invest 2003; 63: 195–202. CrossrefGoogle Scholar

About the article

Corresponding author: Dr. H. Baadenhuijsen, University Hospital Nijmegen, 116 SKML, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands Phone: +31-24-3614767, Fax: +31-24-3560686,


Received: 2004-09-30

Accepted: 2004-12-15

Published Online: 2014-06-05

Published in Print: 2005-03-01


Citation Information: Clinical Chemistry and Laboratory Medicine (CCLM), Volume 43, Issue 3, Pages 304–307, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/CCLM.2005.052.

Export Citation

©2005 by Walter de Gruyter Berlin New York. Copyright Clearance Center

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
Marlou L. A. de Kroon, Carry M. Renders, Jacobus P. van Wouwe, Stef van Buuren, Remy A. Hirasing, and Qamaruddin Nizami
PLoS ONE, 2010, Volume 5, Number 11, Page e13966
[2]
Michel R. Langlois, Olivier S. Descamps, Arnoud van der Laarse, Cas Weykamp, Hannsjörg Baum, Kari Pulkki, Arnold von Eckardstein, Dirk De Bacquer, Jan Borén, Olov Wiklund, Païvi Laitinen, Wytze P. Oosterhuis, and Christa Cobbaert
Atherosclerosis, 2014, Volume 233, Number 1, Page 83
[3]
C. Perich, C. Ricós, V. Alvarez, C. Biosca, B. Boned, F. Cava, M.V. Doménech, P. Fernández-Calle, P. Fernández-Fernández, J.V. García-Lario, J. Minchinela, M. Simón, and R. Jansen
Clinica Chimica Acta, 2014, Volume 432, Page 82
[4]
Rob Jansen, Nuthar Jassam, Annette Thomas, Carmen Perich, Pilar Fernandez-Calle, Ana Paula Faria, Helena Correia, Julian H. Barth, Cas Weykamp, Christa Cobbaert, Marc Thelen, and Carmen Ricós
Clinica Chimica Acta, 2014, Volume 432, Page 90
[5]
David Armbruster
Clinics in Laboratory Medicine, 2013, Volume 33, Number 1, Page 125
[6]
Christa Cobbaert, Cas Weykamp, Paul Franck, Robert de Jonge, Aldy Kuypers, Herman Steigstra, Jacqueline Klein Gunnewiek, Douwe van Loon, and Rob Jansen
Clinica Chimica Acta, 2012, Volume 414, Page 234
[7]
Vincent Delatour, Beatrice Lalere, Karène Saint-Albin, Maryline Peignaux, Jean-Marc Hattchouel, Gilles Dumont, Jacques De Graeve, Sophie Vaslin-Reimann, and Philippe Gillery
Clinica Chimica Acta, 2012, Volume 413, Number 23-24, Page 1872
[8]
Laura Rami, Montserrat Roura, and Francesca Canalias
Clinica Chimica Acta, 2012, Volume 413, Number 15-16, Page 1249
[9]
Hedwig C.M. Stepman, Dietmar Stöckl, Rosana Acheme, Sandra Sesini, Daniel Mazziotta, and Linda M. Thienpont
Clinical Chemistry and Laboratory Medicine, 2011, Volume 49, Number 11
[10]
Francesca Canalias, Ester García, and Maribel Sánchez
Clinica Chimica Acta, 2010, Volume 411, Number 1-2, Page 7
[11]
Rob Jansen, Gerhard Schumann, Henk Baadenhuijsen, Paul Franck, Carlo Franzini, Rolf Kruse, Aldy Kuypers, Cas Weykamp, and Mauro Panteghini
Clinica Chimica Acta, 2006, Volume 368, Number 1-2, Page 160
[12]
Giampaolo Cattozzo, Chiara Albeni, and Carlo Franzini
Clinica Chimica Acta, 2010, Volume 411, Number 11-12, Page 882
[13]
Rob T.P. Jansen and Robbert J. Slingerland
Clinical Chemistry and Laboratory Medicine, 2010, Volume 48, Number 7
[15]
Adriaan J. van Gammeren, Nelly van Gool, Monique J.M. de Groot, and Christa M. Cobbaert
Clinical Chemistry and Laboratory Medicine, 2008, Volume 46, Number 6
[16]
Joris R. Delanghe, Christa Cobbaert, Marie-Madeleine Galteau, Aimo Harmoinen, Rob Jansen, Rolf Kruse, Päivi Laitinen, Linda M. Thienpont, Birgitte Wuyts, Cas Weykamp, and Mauro Panteghini
Clinical Chemistry and Laboratory Medicine, 2008, Volume 46, Number 9
[17]
M. L. A. de Kroon, C. M. Renders, E. C. C. Kuipers, J. P. van Wouwe, S. van Buuren, G. A. de Jonge, and R. A. Hirasing
The European Journal of Public Health, 2008, Volume 18, Number 6, Page 656

Comments (0)

Please log in or register to comment.
Log in