Jump to ContentJump to Main Navigation
Show Summary Details
More options …

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM)

Editor-in-Chief: Plebani, Mario

Ed. by Gillery, Philippe / Lackner, Karl J. / Lippi, Giuseppe / Melichar, Bohuslav / Payne, Deborah A. / Schlattmann, Peter / Tate, Jillian R.

12 Issues per year


IMPACT FACTOR 2016: 3.432

CiteScore 2016: 2.21

SCImago Journal Rank (SJR) 2016: 1.000
Source Normalized Impact per Paper (SNIP) 2016: 1.112

Online
ISSN
1437-4331
See all formats and pricing
More options …
Volume 47, Issue 12 (Dec 2009)

Issues

Screening for M-proteinemia: serum protein electrophoresis and free light chains compared

Andries J. Bakker / Ageeth Bierma-Ram / Coby Elderman-van der Werf / Marcia L. Strijdhaftig / Jelmer J. van Zanden
Published Online: 2009-10-21 | DOI: https://doi.org/10.1515/CCLM.2009.332

Abstract

Background: The objective of this study was to evaluate the efficiency of free light chain (FLC) analysis in comparison to serum protein electrophoresis (SPE) for detecting M-proteinemia.

Methods: A total of 553 consecutive patients for whom evaluation of M-proteinemia was requested were included in this study. For all patients, serum FLC analysis and SPE followed by pentavalent immunofixation analysis was performed. Identification of monoclonal bands was performed using specific antisera. FLC analysis was performed using the Modular P analyzer in accordance with the manufacturer's recommendations. Local reference ranges for FLCs on this platform were established based on samples from patients with a normal electrophoretic pattern [no monoclonal bands, no hypo- or hypergammaglobulinemia, no acute phase pattern and normal kidney function, i.e., estimated glomerular filtration rate (eGFR) >60 mL/min].

Results: Local reference ranges (95%) were established (n=243): κ: 8.01–28.26 mg/L; λ: 8.07–23.58 mg/L and κ/λ ratio: 0.74–1.66. Negative and positive predictive values were 98.6% and 49.5%, respectively, for screening for M-proteinemia by SPE alone, 94.3% and 21.7% for FLC concentration and 95.1% and 21.4% for FLC with the κ/λ-ratio included. Combining protein electrophoresis and FLCs resulted in a negative predictive value of 99.0% and a positive predictive value of 23.4%.

Conclusions: Serum FLC analysis alone is not suitable for screening for M-proteinemia.

Clin Chem Lab Med 2009;47:1507–11.

Keywords: free light chain assay; immunofixation electrophoresis; monoclonal gammopathy; M-proteinemia; multiple myeloma; serum protein electrophoresis

About the article

Corresponding author: A.J. Bakker, PhD, Department of Clinical Chemistry, Klinisch Chemisch Laboratorium, P.O. Box 850, 8901 BR Leeuwarden, The Netherlands Phone: +31-582888444, Fax: +31-582882227,


Received: 2009-07-30

Accepted: 2009-08-20

Published Online: 2009-10-21

Published in Print: 2009-12-01


Citation Information: Clinical Chemistry and Laboratory Medicine, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/CCLM.2009.332.

Export Citation

©2009 by Walter de Gruyter Berlin New York. Copyright Clearance Center

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
Sara Altinier, Mara Seguso, Martina Zaninotto, Mariacristina Varagnolo, Fausto Adami, Paolo Angeli, and Mario Plebani
Clinical Biochemistry, 2013, Volume 46, Number 7-8, Page 691
[3]
Andries J. Bakker, Coby Elderman-van der Werf, and Tjallie van Abbema
Clinical Chemistry and Laboratory Medicine, 2012, Volume 50, Number 1

Comments (0)

Please log in or register to comment.
Log in