Jump to ContentJump to Main Navigation
Show Summary Details
More options …

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM)

Editor-in-Chief: Plebani, Mario

Ed. by Gillery, Philippe / Greaves, Ronda / Lackner, Karl J. / Lippi, Giuseppe / Melichar, Bohuslav / Payne, Deborah A. / Schlattmann, Peter


IMPACT FACTOR 2018: 3.638

CiteScore 2018: 2.44

SCImago Journal Rank (SJR) 2018: 1.191
Source Normalized Impact per Paper (SNIP) 2018: 1.205

Online
ISSN
1437-4331
See all formats and pricing
More options …
Volume 47, Issue 4

Issues

Estimation of trueness of measurement results obtained in external quality assessment

Bedrich Friedecky / Josef Kratochvila / Marek Budina
Published Online: 2009-03-06 | DOI: https://doi.org/10.1515/CCLM.2009.098

Abstract

Background: We demonstrated that lyophilised EQA/PT control materials, under certain circumstances, provide equal information about bias values as pools of native patient sera, and that in some cases, long-term reliable work with such materials is possible.

Methods: Bias values, estimated from results of routine surveys of EQA SEKK (Czech Republic) programmes for eight basic blood serum analytes using lyophilised control materials, were compared with bias values reached in the CAP (USA) programme where pools of native and lyophilised patient sera were used.

Results: Results for the components Na, K, Mg, Cl, P, urea, glucose, and uric acid were assessed. No significant differences were found between the bias values estimated by CAP using native sera, and those estimated by SEKK using lyophilised sera.

Conclusions: It can be concluded that well-prepared lyophilised control materials may show the required commutability level. If so, they constitute a practical and cost-efficient alternative to native or fresh frozen sera when assessing bias.

Clin Chem Lab Med 2009;47:489–90.

Keywords: bias; External Quality Assessment (EQA); lyophilised control material; native control material

About the article

Corresponding author: Josef Kratochvila, SEKK Pardubice, Bartolomejska 90, 53002 Pardubice, Czech Republic Phone: +420-325516388, Fax: +420-325516388,


Received: 2008-09-11

Accepted: 2009-01-09

Published Online: 2009-03-06

Published in Print: 2009-04-01


Citation Information: Clinical Chemistry and Laboratory Medicine, Volume 47, Issue 4, Pages 489–490, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/CCLM.2009.098.

Export Citation

©2009 by Walter de Gruyter Berlin New York.Get Permission

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
Vincent Delatour, Beatrice Lalere, Karène Saint-Albin, Maryline Peignaux, Jean-Marc Hattchouel, Gilles Dumont, Jacques De Graeve, Sophie Vaslin-Reimann, and Philippe Gillery
Clinica Chimica Acta, 2012, Volume 413, Number 23-24, Page 1872
[2]
Woochang Lee, Hee-Jung Chung, Ulf Hannestad, Sollip Kim, Sail Chun, Joong-Yeol Park, Junghan Song, Jin Q. Kim, and Won-Ki Min
Clinical Chemistry and Laboratory Medicine, 2011, Volume 49, Number 6

Comments (0)

Please log in or register to comment.
Log in