Sensitivity and specificity of the high fluorescent lymphocyte count-gate on the Sysmex XE-5000 hematology analyzer for detection of peripheral plasma cells

Edwin van Mirre / Gert Jan Vrielink / Nicole Tjon-a-Tsoi / Henriët Hendriks / Wim de Kieviet / Edwin ten Boekel
Published Online: 2011-03-02 | DOI: https://doi.org/10.1515/CCLM.2011.100

Abstract

Background: Plasma cells are one of the end products of the B-lymphocyte mediated immune response. These cells normally reside in the bone marrow or some peripheral lymphoid tissues. Increased numbers of plasma cells in the blood, usually indicates pathology such as infection, auto-immunity or haematological malignancy. Therefore, the ability to measure plasma cells (PCs) on an automated cell analyzer might be advantageous.

Methods: The performance of the Sysmex XE-5000 leukocyte differential channel [high fluorescent lymphocyte count (HFLC) area] was evaluated for the ability to detect plasma cells in peripheral blood and compared to the detection of plasma cells by flow cytometric analyses.

Results: Our results show that the HFL count from the XE-5000 correlates (R2=0.8) with the number of PCs in peripheral blood, but detects PCs with moderate to good sensitivity (88.9%) and specificity (87.8%).

Conclusions: The Sysmex XE-5000 is suitable for screening blood samples for the presence of elevated number of plasma cells in peripheral blood, but the actual quantification needs to be confirmed by flow cytometry.

Keywords: flow cytometry; hematology analyzer; high fluorescent lymphocyte count (HFLC); plasma cells

About the article

Corresponding author: Dr. E. van Mirre, PhD, Clinical Laboratory, Sint Lucas Andreas Hospital, Jan Tooropstraat 164, 1061 Amsterdam, The Netherlands


Received: 2010-07-15

Accepted: 2010-10-25

Published Online: 2011-03-02

Published in Print: 2011-04-01


Citation Information: Clinical Chemistry and Laboratory Medicine, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/CCLM.2011.100.

Export Citation

©2011 by Walter de Gruyter Berlin New York. Copyright Clearance Center

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
Yaoling Luo, Jianhua Lin, Hao Chen, Jingping Zhang, Songguo Peng, and Miaohuan Kuang
Clinica Chimica Acta, 2013, Volume 422, Page 5

Comments (0)

Please log in or register to comment.
Log in