Validation of the body fluid module on the new Sysmex XN-1000 for counting blood cells in cerebrospinal fluid and other body fluids

Chérina Fleming
  • Department of Clinical Chemistry, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
/ Rob Brouwer
  • Department of Clinical Chemistry, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
/ Jan Lindemans
  • Department of Clinical Chemistry, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
/ Robert de Jonge
  • Corresponding author
  • Department of Clinical Chemistry, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
  • Email:
Published Online: 2012-05-07 | DOI: https://doi.org/10.1515/cclm-2011-0927

Abstract

Background: We evaluated the body fluid (BF) module on the new Sysmex XN-1000 for counting blood cells.

Methods: One hundred and eighty-seven BF samples [73 cerebrospinal fluid (CSF), 48 continuous ambulatory peritoneal dialysis (CAPD), 46 ascites, and 20 pleural fluid] were used for method comparison between the XN-1000 and manual microscopy (Fuchs-Rosenthal chamber and stained cytospin slides) for counting red blood cells (RBCs) and white blood cells (WBCs) (differential).

Results: Good agreement was found for counting WBCs (y=1.06x+0.09, n=67, R2=0.96) and mononuclear cells (MNs) (y=1.04x–0.01, n=40, R2=0.93) in CSF. However, the XN-1000 systematically counted more polymorphonuclear cells (PMNs) (y=1.48x+0.18, n=40, R2=0.99) compared to manual microscopy. Excellent correlation for RBCs >1×109/L (y=0.99x+116.56, n=26, R2=0.99) in CSF was found. For other fluids (CAPD, ascites and pleural fluid) excellent agreement was found for counting WBCs (y=1.06x+0.26, n=109, R2=0.98), MNs (y=1.06x–0.41, n=93, R2=0.96), PMNs (y=1.06x+0.81, n=93, R2=0.98) and RBCs (y=1.04x+110.04, n=43, R2=0.98). By using BF XN-check, the lower limit of quantitation (LLoQ) for WBC was defined at 5×106/L. Linearity was excellent for both the WBCs (R2=0.99) and RBCs (R2=0.99) and carry-over never exceeded 0.05%.

Conclusions: The BF module on the XN-1000 is a suitable tool for fast and accurate quantification of WBC (differential) and RBC counts in CSF and other BFs in a diagnostic setting.

Keywords: body fluid; cerebrospinal fluid; counting chamber; hematology analyzer; leukocytes; Sysmex XN-1000

About the article

Corresponding author: Dr. Robert de Jonge, Department of Clinical Chemistry, L-137, Erasmus MC, University Medical Center Rotterdam, s-Gravendijkwal 230, 3015 CE Rotterdam, The Netherlands Phone: +31 10 7033473, Fax: +31 10 4367894


Received: 2011-12-15

Accepted: 2012-03-22

Published Online: 2012-05-07

Published in Print: 2012-10-01



Citation Information: Clinical Chemistry and Laboratory Medicine, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/cclm-2011-0927. Export Citation

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
Sabrina Buoro, Sara Apassiti Esposito, MariaGrazia Alessio, Alberto Crippa, Cosimo Ottomano, and Giuseppe Lippi
Journal of Clinical Laboratory Analysis, 2015, Page n/a
[2]
D. Labaere, N. Boeckx, I. Geerts, M. Moens, and M. Van den Driessche
International Journal of Laboratory Hematology, 2015, Page n/a
[3]
Linda M. Sandhaus
Clinics in Laboratory Medicine, 2015, Volume 35, Number 1, Page 93
[4]
Y.-U. Cho, H.-S. Chi, S. H. Park, S. Jang, Y.-J. Kim, and C.-J. Park
International Journal of Laboratory Hematology, 2015, Volume 37, Number 3, Page 346
[5]
J. Y. Seo, S.-T. Lee, and S.-H. Kim
International Journal of Laboratory Hematology, 2015, Volume 37, Number 2, Page 155
[6]
Y. Tanaka, H. Matsushita, Y. Tanaka, Y. Maruki, T. Kondo, S. Asai, and H. Miyachi
International Journal of Laboratory Hematology, 2014, Volume 36, Number 1, Page e3

Comments (0)

Please log in or register to comment.
Log in