Volume 51, Issue 4

Issues

Identification and quantification of hemoglobins in whole blood: the analytical and organizational aspects of Capillarys 2 Flex Piercing compared with agarose electrophoresis and HPLC methods

Sara Altinier / Mariacristina Varagnolo / Martina Zaninotto / Mario Plebani
Published Online: 2012-10-12 | DOI: https://doi.org/10.1515/cclm-2012-0061

Abstract

Background: The present study was conducted to evaluate the analytical performance and the organizational aspects of Capillarys 2 Flex Piercing system (CFP) respect to agarose electrophoresis and HPLC methods in hemoglobinopathies screening.

Methods: The measurement of imprecision in HbA2 and HbF quantification was verified on HbA2 CFP control and on three samples; 74 whole blood samples were used to evaluate migration time imprecision of hemoglobin variants S, C and E (HbS, HbC, and HbE); to compare methods, 451 samples were tested on CFP and HPLC; reference values were verified as value distribution in 160 blood donors and at ROC curve analysis on 449 samples from routine analysis.

Results: Imprecision: the analytical CV%s ranged from 1.25 to 3.9 at HbA2 quantification, the CV% was 3.78 at HbF quantification; the running time imprecision for HbS and HbC and HbE ranged from 0.20 to 0.69%. Method comparison: at regression analysis findings were HbA2: CFP=1.21×HPLC–0.64, HbF: CFP=1.31×HPLC-0.75, HbS: CFP=1.10×HPLC-3.24. Reference values: the HbA2 95th percentile range was 2.5–2.8; HbF was undetectable in 154 out 160 samples tested; at ROC curve analysis the best combination of sensitivity and diagnostic efficiency was obtained using 2.2 and 3.0, as reference values, for HbA2 and 1.1 as the upper reference limit for HbF. Organizational aspects: with respect to the procedures currently implemented in our laboratory CFP requires 2 h less time and obviates the need for some manual steps.

Conclusions: The quantification, reproducibility and diagnostic efficiency provided by CFP in identification and quantification of hemoglobins appear accurate. In addition, the use of primary tubes allows improved safety, and the avoidance of some manual steps, that prolong working time and are a source of possible errors.

Keywords: capillary electrophoresis; hemoglobins; HPLC

References

  • 1.

    Vichinsky EP. Changing patterns of thalassemia worldwide. Ann N Y Acad Sci 2005;1054:18–24.Google Scholar

  • 2.

    Pack-Mabien A, Haynes J Jr. A primary care provider’s guide to preventive and acute care management of adults and children with sickle cell disease. J Am Acad Nurse Pract 2009;21:250–7.CrossrefWeb of ScienceGoogle Scholar

  • 3.

    Cogliandro T, Derchi G, Mancuso L, Mayer MC, Pannone B, Pepe A, et al. Society for the Study of Thalassemia and Hemoglobinopathies (SoSTE. Guideline recommendations for heart complications in thalassemia major. J Cardiovasc Med 2008;9:515–25.Web of ScienceCrossrefGoogle Scholar

  • 4.

    Globin gene server. http://globin.cse.psu.edu. Accessed on 10 January 2012.

  • 5.

    Gwendolyn MC, Higgins TN. Laboratory investigation of hemoglobinopathies and thalassemias: review and update. Clin Chem 2000;46:1284–90.Google Scholar

  • 6.

    Mosca A, Paleari R, Leone D, Ivaldi G. The relevance of hemoglobin F measurement in the diagnosis of thalassemias and related hemoglobinopathies. Clin Biochem 2009;42:1797–801.Web of ScienceCrossrefPubMedGoogle Scholar

  • 7.

    Kleinert P, Schmid M, Zurbriggen K, Speer O, Schmugge M, Roschitzki B, et al. Mass spectrometry: a tool for enhanced detection of hemoglobin variants. Clin Chem 2008;54:69–76.PubMedGoogle Scholar

  • 8.

    Gosselin RC, Carlin AC, Dwyre DM. Comparison of the BioRad Variant and Primus Ultra2 high-pressure liquid chromatography (HPLC) instruments for the detection of variant hemoglobins. Int J Lab Hematol 2011;33:159–67.Web of ScienceGoogle Scholar

  • 9.

    Pornprasert S, Kasemrad C, Sukunthamala K. Diagnosis of thalassemia on dried blood spot samples by high performance liquid chromatography. Hemoglobin 2010;34:486–94.CrossrefWeb of SciencePubMedGoogle Scholar

  • 10.

    Higgins T, Mack M, Khajuria A. Comparison of two methods for the quantification and identification of hemoglobin variants. Clin Biochem 2009;42:701–5.CrossrefWeb of SciencePubMedGoogle Scholar

  • 11.

    Ryan K, Bain BJ, Worthington D, James J, Plews D, Mason A, et al. British Committee for Standards in Haematology Significant haemoglobinopathies: guidelines for screening and diagnosis Br J Haematol 2010;149:35–49.Web of ScienceGoogle Scholar

  • 12.

    Louahabi A, Philippe M, Lali S, Wallemacq P, Maisin D. Evaluation of a new Sebia kit for analysis of hemoglobin fractions and variants on the Capillarys system. Clin Chem Lab Med 2006;44:340–5.PubMedGoogle Scholar

  • 13.

    Mosca A, Paleari R, Ivaldi G, Galanello R, Giordano PC. The role of haemoglobin A(2. testing in the diagnosis of thalassaemias and related haemoglobinopathies. J Clin Pathol 2009;62:13–7.CrossrefPubMedWeb of ScienceGoogle Scholar

  • 14.

    Stephens AD, Angastiniotis M, Baysal E, Chan V, Fucharoen S, Giordano PC, et al. ICSH recommendations for the measurement of haemoglobin A2. Int J Lab Hematol 2012;34:1–13.CrossrefPubMedGoogle Scholar

  • 15.

    Yang Z, Chaffin CH, Easley PL, Thigpen B, Reddy VV. Prevalence of elevated hemoglobin A2 measured by the CAPILLARYS system. Am J Clin Pathol 2009;131:42–8.Web of ScienceGoogle Scholar

  • 16.

    Lafferty J. College of American Pathologists hemoglobinopathy survey HG–B. Chicago, IL: College of American Pathologists, 1999.Google Scholar

  • 17.

    Cotton F, Malaviolle X, Vertongen F, Gulbis B. Evaluation of an automated capillary electrophoresis system in the screening for hemoglobinopathies. Clin Lab 2009;55:217–21.PubMedGoogle Scholar

  • 18.

    Higgins TN, Khajuria A, Mack M. Quantification of HbA(2. in patients with and without beta-thalassemia and in the presence of HbS, HbC, HbE, and HbD Punjab hemoglobin variants: comparison of two systems. Am J Clin Pathol 2009;131: 357–62.Web of ScienceGoogle Scholar

  • 19.

    Keren DF, Hedstrom D, Gulbranson R, Ou CN, Bak R. Comparison of Sebia Capillarys capillary electrophoresis with the Primus high-pressure liquid chromatography in the evaluation of hemoglobinopathies Am J Clin Pathol 2008;130:824–31.Web of ScienceGoogle Scholar

  • 20.

    Anagnostopoulos K, Tentes I, Kalleas C, Margaritis D, Toli A, Pendilas D, et al. Effect of HbS in the determination of HbA2 with the Menarini HA-8160 analyzer and comparison with other instruments. Int J Lab Hematol 2009;31:665–72.Web of ScienceCrossrefPubMedGoogle Scholar

  • 21.

    Giambona A, Passarello C, Renda D, Maggio A. The significance of the hemoglobin A2 value in screening for hemoglobinopathies. Clin Biochem 2009;42:1786–96.CrossrefWeb of SciencePubMedGoogle Scholar

  • 22.

    Van Delft P, Lenters E, Bakker-Verweij M, de Korte M, Baylan U, Harteveld CL, et al. Evaluating five dedicated automatic devices for haemoglobinopathy diagnostics in multi-ethnic populations. Int J Lab Hematol 2009;31:484–95.Web of ScienceGoogle Scholar

About the article

Corresponding author: Sara Altinier, Department of Laboratory Medicine, University-Hospital of Padova, Via Giustiniani 2 35128 Padova, Italy, Phone: +39 049 821 8708, Fax: +39 049 8218489


Received: 2012-01-31

Accepted: 2012-09-06

Published Online: 2012-10-12

Published in Print: 2013-04-01


Citation Information: Clinical Chemistry and Laboratory Medicine, Volume 51, Issue 4, Pages 791–797, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/cclm-2012-0061.

Export Citation

©2013 by Walter de Gruyter Berlin Boston.Get Permission

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
Radhouene Doggui, Chaïma Abdelhafidh Sahli, Wassef Lotfi Aissa, Maroua Hammami, Maha Ben Sedrine, Rahma Mahjoub, Khemais Zouaoui, Rim Daboubi, Hajer Siala, Taieb Messaoud, and Amina Bibi
ELECTROPHORESIS, 2017

Comments (0)

Please log in or register to comment.
Log in