Jump to ContentJump to Main Navigation
Show Summary Details
Weitere Optionen …

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM)

Editor-in-Chief: Plebani, Mario

Hrsg. v. Gillery, Philippe / Greaves, Ronda / Lackner, Karl J. / Lippi, Giuseppe / Melichar, Bohuslav / Payne, Deborah A. / Schlattmann, Peter


IMPACT FACTOR 2018: 3.638

CiteScore 2018: 2.44

SCImago Journal Rank (SJR) 2018: 1.191
Source Normalized Impact per Paper (SNIP) 2018: 1.205

Online
ISSN
1437-4331
Alle Formate und Preise
Weitere Optionen …
Band 51, Heft 9

Hefte

High concentration of IgM-κ paraprotein causes over-estimation of serum total protein by certain biuret method

Tze Ping Loh
  • Korrespondenzautor
  • National University Health System, Department of Laboratory Medicine, 5 Lower Kent Ridge Road, Singapore 119074, Singapore
  • E-Mail
  • Weitere Artikel des Autors:
  • De Gruyter OnlineGoogle Scholar
/ Sai Mun Leong
  • Department of Laboratory Medicine, National University Hospital, 5 Lower Kent Ridge Road, Singapore
  • Weitere Artikel des Autors:
  • De Gruyter OnlineGoogle Scholar
/ Sunil Kumar Sethi
  • Department of Laboratory Medicine, National University Hospital, 5 Lower Kent Ridge Road, Singapore
  • Weitere Artikel des Autors:
  • De Gruyter OnlineGoogle Scholar
Online erschienen: 02.04.2013 | DOI: https://doi.org/10.1515/cclm-2013-0160

References

  • 1.

    Loh TP, Saw S, Sethi SK. Hyperphosphatemia in a 56-year-old man with hypochondrial pain. Clin Chem 2010;56:892–5.CrossrefGoogle Scholar

  • 2.

    Imperiali M, Jelmini P, Ferraro B, Keller F, della Bruna R, Balerna M, et al. Interference in thyroid-stimulating hormone determination. Eur J Clin Invest 2010;40:756–8.CrossrefWeb of ScienceGoogle Scholar

  • 3.

    Pantanowitz L, Horowitz GL, Upalakalin JN, Beckwith BA. Artifactual hyperbilirubinemia due to paraprotein interference. Arch Pathol Lab Med 2003;127:55–9.Google Scholar

  • 4.

    Tichy M, Friedecky B, Budina M, Maisnar V, Buchler T, Holeckova M, et al. Interference of IgM-lambda paraprotein with biuret-type assay for total serum protein quantification. Clin Chem Lab Med 2009;47:235–6.Web of ScienceGoogle Scholar

Artikelinformationen

Corresponding author: Tze Ping Loh, National University Health System, Department of Laboratory Medicine, 5 Lower Kent Ridge Road, Singapore 119074, Singapore, Phone: +65 84364247, Fax: +65 67771613


Erhalten: 20.01.2013

Angenommen: 04.03.2013

Online erschienen: 02.04.2013

Erschienen im Druck: 01.09.2013


Quellenangabe: Clinical Chemistry and Laboratory Medicine, Band 51, Heft 9, Seiten e205–e207, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/cclm-2013-0160.

Zitat exportieren

©2013 by Walter de Gruyter Berlin Boston.Get Permission

Kommentare (0)