More on the accuracy of the Architect enzymatic assay for hemoglobin A1c and its traceability to the IFCC reference system

Dominika Szőke / Assunta Carnevale / Sara Pasqualetti / Federica Braga
  • Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Renata Paleari
  • Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Mauro Panteghini
  • Clinical Pathology Unit, “Luigi Sacco” University Hospital, Milan, Italy
  • Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2015-08-18 | DOI: https://doi.org/10.1515/cclm-2015-0550

References

  • 1.

    Teodoro-Morrison T, Janssen MJ, Mols J, Hendrickx BH, Velmans MH, Lotz J, et al. Evaluation of a next generation direct whole blood enzymatic assay for hemoglobin A1c on the ARCHITECT c8000 chemistry system. Clin Chem Lab Med 2015;53:125–32.Google Scholar

  • 2.

    Braga F, Panteghini M. Standardization and analytical goals for glycated hemoglobin measurement. Clin Chem Lab Med 2013;51:1719–26. Erratum in Clin Chem Lab Med 2013;5:2064.Google Scholar

  • 3.

    Abbott ARCHITECT traceability and uncertainty of measurement document 306354/R02, 2013.Google Scholar

  • 4.

    Braga F, Dolci A, Scapellato L, Mosca A, Panteghini M. Fresh-frozen human whole blood for intralaboratory evaluation of imprecision of glycated hemoglobin determination. Biochim Clin 2010;34:203–6.Google Scholar

  • 5.

    Mosca A. Some practical advices on how to implement the international standardization of glycated hemoglobin measurement in Italy. Biochim Clin 2011;35:36–41.Google Scholar

  • 6.

    Mosca A, Weykamp C. Feasibility of an EQAS for HbA1c in Italy using fresh blood samples. Clin Chem Lab Med 2014;52:e151–3.CrossrefWeb of ScienceGoogle Scholar

  • 7.

    Ponzo P, Dolci A, Scapellato L, Milano M, Paleari R, Mosca A, et al. Evaluation of commutability for Cobas Integra analytical system of the EQA materials for hemoglobin A1c. Biochim Clin 2008;32:44–7.Google Scholar

  • 8.

    Panteghini M. Application of traceability concepts to analytical quality control may reconcile total error with uncertainty of measurement. Clin Chem Lab Med 2010;48:7–10.CrossrefWeb of ScienceGoogle Scholar

  • 9.

    Jaisson S, Desmons A, Renard B, Chevelle B, Leroy N, Gillery P. Analytical performances of a new enzymatic assay for hemoglobin A1c. Clin Chim Acta 2014;434:48–52.Web of ScienceGoogle Scholar

About the article

Corresponding author: Dominika Szőke, UOC Patologia Clinica, Azienda Ospedaliera “Luigi Sacco”, Via GB Grassi 74, 20157 Milan, Italy, Phone: +39 02 39042683, Fax: +39 02 39042364, E-mail: ; and Clinical Pathology Unit, “Luigi Sacco” University Hospital, Milan, Italy


Received: 2015-06-11

Accepted: 2015-07-23

Published Online: 2015-08-18

Published in Print: 2016-03-01


Citation Information: Clinical Chemistry and Laboratory Medicine (CCLM), Volume 54, Issue 3, Pages e71–e73, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/cclm-2015-0550.

Export Citation

©2016 by De Gruyter.Get Permission

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[2]
Ilenia Infusino and Mauro Panteghini
Clinical Biochemistry, 2018