Skip to content
Licensed Unlicensed Requires Authentication Published by De Gruyter September 22, 2016

Deciphering a macro-troponin I complex; a case report

  • Janice S.C. Chew-Harris EMAIL logo , Stephen O. Brennan , Christopher M. Florkowski , Richard Troughton and Peter M. George

Acknowledgments

A special thanks to staff at Core Biochemistry for performing TnI measurements and staff at Protein Lab for the electrophoretic work done on this case study. We are also grateful to Dr. Samarina Musaad and Dr. Charles Ng, Labtests Auckland, for measuring TnI on the Siemens platform.

  1. Author contributions: All the authors have accepted responsibility for the entire content of this submitted manuscript and approved submission.

  2. Research funding: None declared.

  3. Employment or leadership: None declared.

  4. Honorarium: None declared.

  5. Competing interests: The funding organization(s) played no role in the study design; in the collection, analysis, and interpretation of data; in the writing of the report; or in the decision to submit the report for publication.

References

1. Warner JV, Marshall GA. High incidence of macrotroponin I with a high-sensitivity troponin I assay. Clin Chem Lab Med 2016; 54:1821-9.10.1515/cclm-2015-1276Search in Google Scholar PubMed

2. Abbott Laboratories. STAT High Sensitive Troponin-I. Package Insert. 3P25 G5-6634/R01 B3P2U0 ed. p. 1–10.Search in Google Scholar

3. Roche Diagnostics GmBH (Mannheim) I. Troponin T hs. 05092744 119 200 ed2013-08. p. 1–6.Search in Google Scholar

4. SIEMENS ADVIA Centaur. TnI-Ultra. 2014-08. p. 1–24.Search in Google Scholar

5. Plebani M, Mion M, Altinier S, Girotto MA, Baldo G, Zaninotto M. False-positive troponin I attributed to a macrocomplex. Clin Chem 2002;48:677–9.10.1093/clinchem/48.4.677Search in Google Scholar

6. Legendre-Bazydlo LA, Haverstick DM, Kennedy JL, Dent JM, Bruns DE. Persistent increase of cardiac troponin I in plasma without evidence of cardiac injury. Clin Chem 2010;56:702–5.10.1373/clinchem.2009.138164Search in Google Scholar PubMed

7. Krintus M, Kozinski M, Boudry P, Capell NE, Köller U, Lackner K, et al. European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay. Clin Chem Lab Med 2014;52:1657–65.10.1515/cclm-2014-0107Search in Google Scholar PubMed

8. Panteghini M. Assay-related issues in the measurement of cardiac troponins. Clin Chim Acta 2009;402:88–93.10.1016/j.cca.2008.12.037Search in Google Scholar PubMed

9. Wu AH, Feng Y-J, Moore R, Apple FS, McPherson PH, Buechler KF, et al. Characterization of cardiac troponin subunit release into serum after acute myocardial infarction and comparison of assays for troponin T and I. Clin Chem 1998;44:1198–208.10.1093/clinchem/44.6.1198Search in Google Scholar

Received: 2016-6-7
Accepted: 2016-8-8
Published Online: 2016-9-22
Published in Print: 2017-3-1

©2017 Walter de Gruyter GmbH, Berlin/Boston

Downloaded on 19.3.2024 from https://www.degruyter.com/document/doi/10.1515/cclm-2016-0490/html