Jump to ContentJump to Main Navigation
Show Summary Details
More options …

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM)

Editor-in-Chief: Plebani, Mario

Ed. by Gillery, Philippe / Greaves, Ronda / Lackner, Karl J. / Lippi, Giuseppe / Melichar, Bohuslav / Payne, Deborah A. / Schlattmann, Peter


IMPACT FACTOR 2017: 3.556

CiteScore 2018: 2.44

SCImago Journal Rank (SJR) 2018: 1.191
Source Normalized Impact per Paper (SNIP) 2018: 1.205

Online
ISSN
1437-4331
See all formats and pricing
More options …
Volume 57, Issue 6

Issues

Influence of temperature of transport of whole blood on plasma Cu, I, Mn, Se and Zn and Mg concentrations in erythrocytes

Benoit Chovelon
  • Corresponding author
  • Institute of Biology and Pathology, IBP R2, University Hospital of Grenoble and Alps, CS 10217, 38043 Grenoble cedex 9, France
  • University Grenoble Alpes, DPM UMR 5063, Grenoble, France
  • Email
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Josiane Arnaud
  • Institute of Biology and Pathology, University Hospital of Grenoble and Alps, Grenoble, France
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2018-10-23 | DOI: https://doi.org/10.1515/cclm-2018-0833

References

  • 1.

    Lippi G, Chance JJ, Church S, Dazzi P, Fontana R, Giavarina D, et al. Preanalytical quality improvement: from dream to reality. Clin Chem Lab Med 2011;49:1113–26.PubMedWeb of ScienceGoogle Scholar

  • 2.

    http://www.meteo-grenoble.com. Accessed: 26 July 2018.

  • 3.

    Tamura T, Johnston KE, Freeberg LE, Perkins LL, Goldenberg RL. Refrigeration of blood samples before separation is essential for the accurate determination of plasma or serum zinc concentrations. Biol Trace Elem Res 1994;41:165–73.CrossrefPubMedGoogle Scholar

  • 4.

    Wang RY, Caldwell KL, Jones RL. Analytical considerations in the clinical laboratory assessment of metals. J Med Toxicol 2014;10:232–9.CrossrefPubMedGoogle Scholar

  • 5.

    Chovelon B, Arnaud J. Influence of delayed separation of plasma from whole blood on Cu, I, Mn, Se, and Zn plasma concentrations. Clin Chem Lab Med 2018;56:e69–71.PubMedWeb of ScienceCrossrefGoogle Scholar

  • 6.

    Oddoze C, Lombard E, Portugal H. Stability study of 81 analytes in human whole blood, in serum and in plasma. Clin Biochem 2012;45:464–9.Web of ScienceCrossrefPubMedGoogle Scholar

  • 7.

    Petersen PH, Fraser CG, Lund F, Sölétormos G. Confirmation of analytical performance characteristics required for the reference change value applied in patient monitoring. Scand J Clin Lab Invest 2015;75:628–30.CrossrefWeb of SciencePubMedGoogle Scholar

  • 8.

    Ricos C, Alvarez V, Cava F, Garcia-Lario JV, Hernandez A, Jimenez CV, et al. Current databases on biologic variation: pros, cons and progress. Scand J Clin Lab Invest 1999;59:491–500. Available at: https://www.westgard.com/biodatabase1.htm. Accessed: 26 April 2018.Crossref

About the article

Received: 2018-08-03

Accepted: 2018-09-25

Published Online: 2018-10-23

Published in Print: 2019-05-27


Author contributions: All the authors have accepted responsibility for the entire content of this submitted manuscript and approved submission.

Research funding: None declared.

Employment or leadership: None declared.

Honorarium: None declared.

Competing interests: The funding organization(s) played no role in the study design; in the collection, analysis and interpretation of data; in the writing of the report; or in the decision to submit the report for publication.


Citation Information: Clinical Chemistry and Laboratory Medicine (CCLM), Volume 57, Issue 6, Pages e131–e133, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/cclm-2018-0833.

Export Citation

©2019 Walter de Gruyter GmbH, Berlin/Boston.Get Permission

Comments (0)

Please log in or register to comment.
Log in