Erroneous thyroid and steroid hormones profile due to anti-streptavidin antibodies

Jean-Louis Bayart
  • Département des laboratoires cliniques, Cliniques Universitaires St. Luc – Université Catholique de Louvain, Brussels, Belgium
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Julien Favresse
  • Département des laboratoires cliniques, Cliniques Universitaires St. Luc – Université Catholique de Louvain, Brussels, Belgium
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Ekaterina Melnik
  • Département des laboratoires cliniques, Cliniques Universitaires St. Luc – Université Catholique de Louvain, Brussels, Belgium
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Benjamin Lardinois
  • Département des laboratoires cliniques, CHU – Mont-Godinne – Université Catholique de Louvain, Yvoir, Belgium
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Catherine Fillée
  • Département des laboratoires cliniques, Cliniques Universitaires St. Luc – Université Catholique de Louvain, Brussels, Belgium
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Dominique Maiter
  • Service d’endocrinologie et nutrition, Cliniques Universitaires St. Luc – Université Catholique de Louvain, Brussels, Belgium
  • Pôle de recherche en Endocrinologie, Diabète et Nutrition, Institut de Recherche Expérimentale et Clinique, Cliniques Universitaires St. Luc – Université Catholique de Louvain, Tour Claude Bernard, Brussels, Belgium
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Pr. Damien Gruson
  • Corresponding author
  • Département des laboratoires cliniques, Cliniques Universitaires St. Luc – Université Catholique de Louvain, Brussels, Belgium
  • Pôle de recherche en Endocrinologie, Diabète et Nutrition, Institut de Recherche Expérimentale et Clinique, Cliniques Universitaires St. Luc – Université Catholique de Louvain, Tour Claude Bernard, Brussels, Belgium
  • Email
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2019-03-23 | DOI: https://doi.org/10.1515/cclm-2018-1355

References

  • 1.

    Clerico A, Belloni L, Carrozza C, Correale M, Dittadi R, Dotti C, et al. A Black Swan in clinical laboratory practice: the analytical error due to interferences in immunoassay methods. Clin Chem Lab Med 2018;56:397–402.Web of SciencePubMedCrossrefGoogle Scholar

  • 2.

    Favresse J, Burlacu M-C, Maiter D, Gruson D. Interferences with thyroid function immunoassays: clinical implications and detection algorithm. Endocr Rev 2018;39:830–50.PubMedWeb of ScienceCrossrefGoogle Scholar

  • 3.

    Leslie H, Courtney C, Bell P, Hadden D, McCance D, Ellis P, et al. Laboratory and clinical experience in 55 patients with macroprolactinemia identified by a simple polyethylene glycol precipitation method. J Clin Endocrinol Metab 2001;86:2743–6.PubMedCrossrefGoogle Scholar

  • 4.

    Langlois F, Moramarco J, He G, Carr BR. Falsely elevated steroid hormones in a postmenopausal woman due to laboratory interference. J Endocr Soc 2017;1:1062–6.Web of ScienceCrossrefGoogle Scholar

  • 5.

    Bjerner J, Nustad K, Norum LF, Olsen KH, Børmer OP. Immunometric assay interference: incidence and prevention. Clin Chem 2002;48:613–21.PubMedGoogle Scholar

  • 6.

    Piketty M-L, Prie D, Sedel F, Bernard D, Hercend C, Chanson P, et al. High-dose biotin therapy leading to false biochemical endocrine profiles: validation of a simple method to overcome biotin interference. Clin Chem Lab Med 2017;55:817–25.Web of SciencePubMedCrossrefGoogle Scholar

  • 7.

    Berth M, Willaert S, De Ridder C. Anti-streptavidin IgG antibody interference in anti-cyclic citrullinated peptide (CCP) IgG antibody assays is a rare but important cause of false-positive anti-CCP results. Clin Chem Lab Med 2018;56:1263–8.CrossrefPubMedWeb of ScienceGoogle Scholar

  • 8.

    Lam L, Bagg W, Smith G, Chiu W, Middleditch MJ, Lim JC-H, et al. Apparent hyperthyroidism caused by biotin-like interference from IgM anti-streptavidin antibodies. Thyroid 2018;28:1063–7.CrossrefWeb of SciencePubMedGoogle Scholar

  • 9.

    Peltier L, Massart C, Moineau M-P, Delhostal A, Roudaut N. Anti-streptavidin interferences in Roche thyroid immunoassays: a case report. Clin Chem Lab Med 2016;54:e11–4.PubMedWeb of ScienceGoogle Scholar

  • 10.

    Rulander NJ, Cardamone D, Senior M, Snyder PJ, Master SR. Interference from anti-streptavidin antibody. Arch Pathol Lab Med 2013;137:1141–6.CrossrefPubMedWeb of ScienceGoogle Scholar

About the article

Corresponding author: Pr. Damien Gruson, Pôle de recherche en Endocrinologie, Diabète et Nutrition, Institut de Recherche Expérimentale et Clinique, Cliniques Universitaires St. Luc – Université Catholique de Louvain, Tour Claude Bernard, 54 Avenue Hippocrate, 1200 Brussels, Belgium; and Département des laboratoires cliniques, Cliniques Universitaires St. Luc – Université Catholique de Louvain, Brussels, Belgium, Phone: +32-(0)2-7646747, Fax: +32-(0)2-7646930


Received: 2018-12-20

Accepted: 2019-02-21

Published Online: 2019-03-23


Author contributions: All the authors have accepted responsibility for the entire content of this submitted manuscript and approved submission.

Research funding: None declared.

Employment or leadership: None declared.

Honorarium: None declared.

Competing interests: The funding organization(s) played no role in the study design; in the collection, analysis, and interpretation of data; in the writing of the report; or in the decision to submit the report for publication.


Citation Information: Clinical Chemistry and Laboratory Medicine (CCLM), 20181355, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/cclm-2018-1355.

Export Citation

©2019 Walter de Gruyter GmbH, Berlin/Boston.Get Permission

Comments (0)

Please log in or register to comment.
Log in