Jump to ContentJump to Main Navigation
Show Summary Details
More options …

Clinical Chemistry and Laboratory Medicine (CCLM)

Published in Association with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM)

Editor-in-Chief: Plebani, Mario

Ed. by Gillery, Philippe / Greaves, Ronda / Lackner, Karl J. / Lippi, Giuseppe / Melichar, Bohuslav / Payne, Deborah A. / Schlattmann, Peter


IMPACT FACTOR 2018: 3.638

CiteScore 2018: 2.44

SCImago Journal Rank (SJR) 2018: 1.191
Source Normalized Impact per Paper (SNIP) 2018: 1.205

Online
ISSN
1437-4331
See all formats and pricing
More options …
Ahead of print

Issues

Utility of the icteric index for the management of bilirubin test requesting

Ariadna Arbiol-Roca
  • Corresponding author
  • Laboratori Clínic L’Hospitalet – Laboratori Clínic Territorial Metropolitana Sud. Institut Català de la Salut. Hospitalet de Llobregat, Barcelona, Spain, Phone: +34932607500
  • Email
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Maria Rosa Navarro-Badal
  • Laboratori Clínic L’Hospitalet – Laboratori Clínic Territorial Metropolitana Sud. Institut Català de la Salut. Hospitalet de Llobregat, Barcelona, Spain
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Blanca Allende-Monclús
  • Laboratori Clínic L’Hospitalet – Laboratori Clínic Territorial Metropolitana Sud. Institut Català de la Salut. Hospitalet de Llobregat, Barcelona, Spain
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2019-06-13 | DOI: https://doi.org/10.1515/cclm-2019-0193

References

  • 1.

    Carraro P, Plebani M. Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem 2007;53:1338–42.CrossrefWeb of ScienceGoogle Scholar

  • 2.

    Lippi B. Governance of preanalytical variability: travelling the right path to the bright side of the moon? Clin Chim Acta 2009;404:32–6.CrossrefPubMedWeb of ScienceGoogle Scholar

  • 3.

    Dufour DR, Lott JA, Nolte FS, Gretch DR, Koff RS, Seeff LB. Diagnosis and monitoring of hepatic injury. II. Recommendations for use of laboratory tests in screening, diagnosis, and monitoring. Clin Chem 2000;46:2050–68.PubMedGoogle Scholar

  • 4.

    Guder WG, Fonseca-Wollheim FD, Heil W, Schmitt YM, Töpfer G, Wisser H, et al. The haemolytic, icteric and lipemic sample. Recommendations regarding their recognition and prevention of clinically relevant interferences. J Lab Med 2000;24:357–64.Google Scholar

  • 5.

    Ferraro S, Panteghini M. The role of laboratory in ensuring appropriate test requests. Clin Biochem 2017;50:555–61.CrossrefPubMedWeb of ScienceGoogle Scholar

  • 6.

    Salinas M, López-Garrigós M, Lugo J, Gutiérrez M, Flors L, Leiva-Salinas C. Diagnostic accuracy of icteric index to detect abnormal total bilirubin values. J Clin Pathol 2012;65:928–33.PubMedWeb of ScienceCrossrefGoogle Scholar

  • 7.

    Szoke D, Braga F, Valente C, Panteghini M. Measurement of icteric index as approach to detect abnormal total bilirubin values. J Clin Pathol 2013;66:1095–7.CrossrefPubMedWeb of ScienceGoogle Scholar

About the article

Received: 2019-02-25

Accepted: 2019-02-28

Published Online: 2019-06-13


Author contributions: All the authors have accepted responsibility for the entire content of this submitted manuscript and approved submission.

Research funding: None declared.

Employment or leadership: None declared.

Honorarium: None declared.

Competing interests: The funding organization(s) played no role in the study design; in the collection, analysis, and interpretation of data; in the writing of the report; or in the decision to submit the report for publication.


Citation Information: Clinical Chemistry and Laboratory Medicine (CCLM), 20190193, ISSN (Online) 1437-4331, ISSN (Print) 1434-6621, DOI: https://doi.org/10.1515/cclm-2019-0193.

Export Citation

© 2019 Walter de Gruyter GmbH, Berlin/Boston.Get Permission

Comments (0)

Please log in or register to comment.