Expansion characteristics of coronary stents in focal stenoses

Wolfram Schmidt
  • Corresponding author
  • Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, Germany
  • Email
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Klaus-Peter Schmitz
  • Institute for ImplantTechnology and Biomaterials and Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, Germany
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Peter Behrens
  • Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, Germany
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Niels Grabow
  • Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, Germany
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Hüseyin Ince
  • Dept. for Cardiology, Center for Internal Medicine, University Medicine, University of Rostock, Ernst-Heydemann-Straße 6, 18057 Rostock, Germany
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Alper Öner
  • Dept. for Cardiology, Center for Internal Medicine, University Medicine, University of Rostock, Ernst-Heydemann-Straße 6, 18057 Rostock, Germany
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2017-09-07 | DOI: https://doi.org/10.1515/cdbme-2017-0029

Abstract

The presented experimental in vitro approach was designed to assess the expansion behavior of stent systems in a resistant focal stenosis model with respect to a potential dog-boning effect. Five different stent systems (nominal diameter 3.0 mm) were investigated. The focal stenosis was simulated by a stainless steel tube (ID ≤ 1.20 mm). Stent expansion was performed using a proprietary test device consisting of a test chamber with 37 °C water, 2-axis laser scanner and a pressure controller.

All stents could be properly expanded up to recommended maximum pressure (RBP). At nominal pressure (NP) maximum diameters ranged from 2.923 to 3.560 mm while at RBP the maximum diameters were 3.391 to 3.984 mm. Only minimal flaring of stent struts from the expanded balloon was observed. None of the stent systems failed under the extremely high stress at the edges of the focal stenosis.

Keywords: Cardiovascular Intervention; biomechanics; stent expansion; dog-boning