Jump to ContentJump to Main Navigation
Show Summary Details
More options …

Current Directions in Biomedical Engineering

Joint Journal of the German Society for Biomedical Engineering in VDE and the Austrian and Swiss Societies for Biomedical Engineering

Editor-in-Chief: Dössel, Olaf

Editorial Board: Augat, Peter / Buzug, Thorsten M. / Haueisen, Jens / Jockenhoevel, Stefan / Knaup-Gregori, Petra / Kraft, Marc / Lenarz, Thomas / Leonhardt, Steffen / Malberg, Hagen / Penzel, Thomas / Plank, Gernot / Radermacher, Klaus M. / Schkommodau, Erik / Stieglitz, Thomas / Urban, Gerald A.


CiteScore 2018: 0.47

Source Normalized Impact per Paper (SNIP) 2018: 0.377

Open Access
Online
ISSN
2364-5504
See all formats and pricing
More options …

Automatic anatomical calibration for IMU-based elbow angle measurement in disturbed magnetic fields

Daniel Laidig / Philipp Müller / Thomas Seel
Published Online: 2017-09-07 | DOI: https://doi.org/10.1515/cdbme-2017-0035

Abstract

Inertial Measurement Units (IMUs) are increasingly used for human motion analysis. However, two major challenges remain: First, one must know precisely in which orientation the sensor is attached to the respective body segment. This is commonly achieved by accurate manual placement of the sensors or by letting the subject perform tedious calibration movements. Second, standard methods for inertial motion analysis rely on a homogeneous magnetic field, which is rarely found in indoor environments. To address both challenges, we introduce an automatic calibration method for joints with two degrees of freedom such as the combined radioulnar and elbow joint. While the user performs arbitrary movements, the method automatically identifies the sensor-to-segment orientations by exploiting the kinematic constraints of the joint. Simultaneously, the method identifies and compensates the influence of magnetic disturbances on the sensor orientation quaternions and the joint angles. In experimental trials, we obtain angles that agree well with reference values from optical motion capture. We conclude that the proposed method overcomes mounting and calibration restrictions and improves measurement accuracy in indoor environments. It therefore improves the practical usability of IMUs for many medical applications.

Keywords: Automatic anatomical calibration; sensor-to-segment calibration; elbow joint; kinematic constraints

About the article

Published Online: 2017-09-07


Citation Information: Current Directions in Biomedical Engineering, Volume 3, Issue 2, Pages 167–170, ISSN (Online) 2364-5504, DOI: https://doi.org/10.1515/cdbme-2017-0035.

Export Citation

©2017 Daniel Laidig et al., published by De Gruyter, Berlin/Boston. This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License. BY-NC-ND 4.0

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
Sébastien Cordillet, Nicolas Bideau, Benoit Bideau, and Guillaume Nicolas
Sensors, 2019, Volume 19, Number 11, Page 2474
[2]
Nicolas Valencia-Jimenez, Arnaldo Leal-Junior, Leticia Avellar, Laura Vargas-Valencia, Pablo Caicedo-Rodríguez, Andrés Ramírez-Duque, Mariana Lyra, Carlos Marques, Teodiano Bastos, and Anselmo Frizera
Electronics, 2019, Volume 8, Number 2, Page 173
[3]
Eric Frick and Salam Rahmatalla
Sensors, 2018, Volume 18, Number 4, Page 1089

Comments (0)

Please log in or register to comment.
Log in