Jump to ContentJump to Main Navigation
Show Summary Details
Weitere Optionen …

Current Directions in Biomedical Engineering

Joint Journal of the German Society for Biomedical Engineering in VDE and the Austrian and Swiss Societies for Biomedical Engineering

Editor-in-Chief: Dössel, Olaf

Wissenschaftlicher Beirat: Augat, Peter / Buzug, Thorsten M. / Haueisen, Jens / Jockenhoevel, Stefan / Knaup-Gregori, Petra / Kraft, Marc / Lenarz, Thomas / Leonhardt, Steffen / Malberg, Hagen / Penzel, Thomas / Plank, Gernot / Radermacher, Klaus M. / Schkommodau, Erik / Stieglitz, Thomas / Urban, Gerald A.


CiteScore 2018: 0.47

Source Normalized Impact per Paper (SNIP) 2018: 0.377

Open Access
Online
ISSN
2364-5504
Alle Formate und Preise
Weitere Optionen …

Automatic anatomical calibration for IMU-based elbow angle measurement in disturbed magnetic fields

Daniel Laidig / Philipp Müller / Thomas Seel
Online erschienen: 07.09.2017 | DOI: https://doi.org/10.1515/cdbme-2017-0035

Abstract

Inertial Measurement Units (IMUs) are increasingly used for human motion analysis. However, two major challenges remain: First, one must know precisely in which orientation the sensor is attached to the respective body segment. This is commonly achieved by accurate manual placement of the sensors or by letting the subject perform tedious calibration movements. Second, standard methods for inertial motion analysis rely on a homogeneous magnetic field, which is rarely found in indoor environments. To address both challenges, we introduce an automatic calibration method for joints with two degrees of freedom such as the combined radioulnar and elbow joint. While the user performs arbitrary movements, the method automatically identifies the sensor-to-segment orientations by exploiting the kinematic constraints of the joint. Simultaneously, the method identifies and compensates the influence of magnetic disturbances on the sensor orientation quaternions and the joint angles. In experimental trials, we obtain angles that agree well with reference values from optical motion capture. We conclude that the proposed method overcomes mounting and calibration restrictions and improves measurement accuracy in indoor environments. It therefore improves the practical usability of IMUs for many medical applications.

Keywords: Automatic anatomical calibration; sensor-to-segment calibration; elbow joint; kinematic constraints

Artikelinformationen

Online erschienen: 07.09.2017


Quellenangabe: Current Directions in Biomedical Engineering, Band 3, Heft 2, Seiten 167–170, ISSN (Online) 2364-5504, DOI: https://doi.org/10.1515/cdbme-2017-0035.

Zitat exportieren

©2017 Daniel Laidig et al., published by De Gruyter, Berlin/Boston. This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License. BY-NC-ND 4.0

Zitierende Artikel

Hier finden Sie eine Übersicht über alle Crossref-gelisteten Publikationen, in denen dieser Artikel zitiert wird. Um automatisch über neue Zitierungen dieses Artikels informiert zu werden, aktivieren Sie einfach oben auf dieser Seite den „E-Mail-Alert: Neu zitiert“.

[1]
Sébastien Cordillet, Nicolas Bideau, Benoit Bideau, and Guillaume Nicolas
Sensors, 2019, Jahrgang 19, Nummer 11, Seite 2474
[2]
Nicolas Valencia-Jimenez, Arnaldo Leal-Junior, Leticia Avellar, Laura Vargas-Valencia, Pablo Caicedo-Rodríguez, Andrés Ramírez-Duque, Mariana Lyra, Carlos Marques, Teodiano Bastos, and Anselmo Frizera
Electronics, 2019, Jahrgang 8, Nummer 2, Seite 173
[3]
Eric Frick and Salam Rahmatalla
Sensors, 2018, Jahrgang 18, Nummer 4, Seite 1089