Volumetric 3D stitching of optical coherence tomography volumes

Max-Heinrich Laves / Lüder A. Kahrs / Tobias Ortmaier
Published Online: 2018-09-22 | DOI: https://doi.org/10.1515/cdbme-2018-0079

Abstract

Optical coherence tomography (OCT) is a noninvasive medical imaging modality, which provides highresolution transectional images of biological tissue. However, its potential is limited due to a relatively small field of view. To overcome this drawback, we describe a scheme for fully automated stitching of multiple 3D OCT volumes for panoramic imaging. The voxel displacements between two adjacent images are calculated by extending the Lucas-Kanade optical flow a lgorithm to dense volumetric images. A RANSAC robust estimator is used to obtain rigid transformations out of the resulting flow v ectors. T he i mages a re t ransformed into the same coordinate frame and overlapping areas are blended. The accuracy of the proposed stitching scheme is evaluated on two datasets of 7 and 4 OCT volumes, respectively. By placing the specimens on a high-accuracy motorized translational stage, ground truth transformations are available. This results in a mean translational error between two adjacent volumes of 16.6 ± 0.8 μm (2.8 ± 0.13 voxels). To the author’s knowledge, this is the first reported stitching of multiple 3D OCT volumes by using dense voxel information in the registration process. The achieved results are sufficient for providing high accuracy OCT panoramic images. Combined with a recently available high-speed 4D OCT, our method enables interactive stitching of hand-guided acquisitions.

Keywords: medical imaging; image processing; registration; panoramic imaging; mosaicing; optical flow

About the article

Published Online: 2018-09-22

Published in Print: 2018-09-01


Citation Information: Current Directions in Biomedical Engineering, Volume 4, Issue 1, Pages 327–330, ISSN (Online) 2364-5504, DOI: https://doi.org/10.1515/cdbme-2018-0079.

Export Citation

© 2018 by Walter de Gruyter Berlin/Boston.Get Permission