Jump to ContentJump to Main Navigation
Show Summary Details
More options …

Current Directions in Biomedical Engineering

Joint Journal of the German Society for Biomedical Engineering in VDE and the Austrian and Swiss Societies for Biomedical Engineering

Editor-in-Chief: Dössel, Olaf

Editorial Board: Augat, Peter / Buzug, Thorsten M. / Haueisen, Jens / Jockenhoevel, Stefan / Knaup-Gregori, Petra / Kraft, Marc / Lenarz, Thomas / Leonhardt, Steffen / Malberg, Hagen / Penzel, Thomas / Plank, Gernot / Radermacher, Klaus M. / Schkommodau, Erik / Stieglitz, Thomas / Urban, Gerald A.

Open Access
Online
ISSN
2364-5504
See all formats and pricing
More options …

Synchronized Sensor Insoles for Clinical Gait Analysis in Home-Monitoring Applications

Nils Roth
  • Corresponding author
  • Machine Learning and Data Analytics Lab, Department of Computer Science, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Email
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Christine F. Martindale
  • Machine Learning and Data Analytics Lab, Department of Computer Science, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Bjoern M. Eskofier
  • Machine Learning and Data Analytics Lab, Department of Computer Science, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Heiko Gaßner / Zacharias Kohl / Jochen Klucken
Published Online: 2018-09-22 | DOI: https://doi.org/10.1515/cdbme-2018-0103

Abstract

Wearable sensor systems are of increasing interest in clinical gait analysis. However, little information about gait dynamics of patients under free living conditions is available, due to the challenges of integrating such systems unobtrusively into a patient’s everyday live. To address this limitation, new, fully integrated low power sensor insoles are proposed, to target applications particularly in home-monitoring scenarios. The insoles combine inertial as well as pressure sensors and feature wireless synchronization to acquire biomechanical data of both feet with a mean timing offset of 15.0 μs. The proposed system was evaluated on 15 patients with mild to severe gait disorders against the GAITRite® system as reference. Gait events based on the insoles’ pressure sensors were manually extracted to calculate temporal gait features such as double support time and double support. Compared to the reference system a mean error of 0.06 s ±0.06 s and 3.89 % ±2.61 % was achieved, respectively. The proposed insoles proved their ability to acquire synchronized gait parameters and address the requirements for home-monitoring scenarios, pushing the boundaries of clinical gait analysis.

Keywords: Gait; Insole; Home-monitoring; Synchronization; Double Support