Concept of a multi sensor and freely configurable patient table for CT applications

Mathias Leopold / Thomas Hoffmann / Klemens Opfermann / Enrico Pannicke / Georg Rose / Elmar Woschke
  • Institute for mechanical engineering, Otto von Guericke University Magdeburg, Magdeburg, Germany
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2018-09-22 | DOI: https://doi.org/10.1515/cdbme-2018-0120

Abstract

Conventional computed tomography (CT) systems are encapsulated in hardware and software. Integration of further imaging modalities and sensors which can acquire prior knowledge for dose saving image acquisition and reconstruction techniques are barely possible. Within the scope of our research project, an open interface and freely configurable CT system is now being developed. The integration of further modalities and sensors into this system is a main target. A subproject deals with a multi sensor patient table, which provides additional information through integrated sensors. In particular, force sensors are installed inside the patient table to determine the patient’s mass. This value can be used to specify the required tube voltage, so that a more precise setting can be made in comparison to today‘s clinical practice. Studys show that a more precise kVp estimation can significantly reduce patient dose. Sensors for the monitoring of respiration and pulse are also integrated into the setup of the patient table. On the one hand, these are designed to encourage the patients to minimize disturbing movements and on the other hand to generate trigger signals for the examination. In addition to the sensor concept of the table, a position control system for vertical and horizontal movement of the table is integrated. The position of the table can be adjusted using different input devices so that a fast and intuitive handling of the table movement can be achieved for standard diagnostic and CT guided interventional procedures. The communication between all sensors, actors and the CT ist realized via the Robot Operating System (ROS) framework.

Keywords: patient table; CT; computed tomography; data acquisition; vitality functions; image reconstruction; dose reduction; multimodality; open interface; ROS

About the article

Published Online: 2018-09-22

Published in Print: 2018-09-01


Citation Information: Current Directions in Biomedical Engineering, Volume 4, Issue 1, Pages 501–504, ISSN (Online) 2364-5504, DOI: https://doi.org/10.1515/cdbme-2018-0120.