Jump to ContentJump to Main Navigation
Show Summary Details
More options …

Diagnosis

Official Journal of the Society to Improve Diagnosis in Medicine (SIDM)

Editor-in-Chief: Graber, Mark L. / Plebani, Mario

Ed. by Argy, Nicolas / Epner, Paul L. / Lippi, Giuseppe / Singhal, Geeta / McDonald, Kathryn / Singh, Hardeep / Newman-Toker, David

Editorial Board: Basso , Daniela / Crock, Carmel / Croskerry, Pat / Dhaliwal, Gurpreet / Ely, John / Giannitsis, Evangelos / Katus, Hugo A. / Laposata, Michael / Lyratzopoulos, Yoryos / Maude, Jason / Sittig, Dean F. / Sonntag, Oswald / Zwaan, Laura

Online
ISSN
2194-802X
See all formats and pricing
More options …

Can citrate plasma be used in exceptional circumstances for some clinical chemistry and immunochemistry tests?

Davide Demonte / Mairi Pucci / Gian Luca Salvagno / Giuseppe Lippi
Published Online: 2019-05-04 | DOI: https://doi.org/10.1515/dx-2019-0027

Abstract

Background

The use of alternative sample matrices may be an advantageous perspective when the laboratory falls short of serum or lithium-heparin plasma for performing clinical chemistry and/or immunochemistry testing. This study was aimed at exploring whether some tests may be performed in citrate plasma as an alternative to lithium-heparin plasma.

Methods

Paired lithium-heparin and citrate plasma samples collected from 55 inpatients were analyzed on Roche Cobas 8000 for 28 different clinical chemistry and immunochemistry parameters. Data obtained in citrate plasma were adjusted for either the dilution factor or using an equation corresponding to the linear regression calculated by comparing unadjusted lithium-heparin and citrate plasma values.

Results

Except for magnesium (+17%) and sodium (+11%), unadjusted values of all remaining analytes were significantly lower in citrate than in lithium-heparin plasma, with bias ranging between −6.4% and −25.9%. The correlation between lithium-heparin and citrate plasma values was generally excellent (i.e. >0.90). The adjustment of citrate plasma values for the dilution factor (i.e. 1.1) was only effective in harmonizing the results of albumin and lipase, whilst the concentration of all other analytes remained significantly different between the two sample matrices. The adjustment of plasma citrate values using corrective formulas was instead effective in harmonizing all parameters, with no results remaining statistically different between the two sample matrices.

Conclusions

Citrate plasma may be used in exceptional circumstances for clinical chemistry and immunochemistry testing as a replacement for lithium-heparin plasma, provided that citrate plasma values are adjusted by using validated corrective equations.

Keywords: citrate; clinical chemistry; lithium-heparin; preanalytical variability

References

  • 1.

    Plebani M. Clinical laboratory: bigger is not always better.Diagnosis (Berl) 2018;5:41–6.CrossrefPubMedGoogle Scholar

  • 2.

    Lippi G, Giavarina D, Gelati M, Salvagno GL. Reference range of hemolysis index in serum and lithium-heparin plasma measured with two analytical platforms in a population of unselected outpatients. Clin Chim Acta 2014;429:143–6.CrossrefWeb of ScienceGoogle Scholar

  • 3.

    Lippi G, Lampus S, Danese E, Montagnana M, Salvagno GL. Values and stability of serum (or plasma) indices in uncentrifuged serum and lithium-heparin plasma. Diagnosis (Berl) 2019;6:45–7.PubMedGoogle Scholar

  • 4.

    Plebani M, Banfi G, Bernardini S, Bondanini F, Conti L, Dorizzi R, et al. Serum or plasma? An old question awaiting for new answers. Biochim Clin, 2019; in press. DOI: CrossrefGoogle Scholar

  • 5.

    Lippi G, Giavarina D. A survey on sample matrix and preanalytical management in clinical laboratories. Biochim Clin 2017;41:142–7.Web of ScienceGoogle Scholar

  • 6.

    Lippi G. The irreplaceable value of laboratory diagnostics: four recent tests that have revolutionized clinical practice. EJIFCC 2019;30:7–13.PubMedGoogle Scholar

  • 7.

    Cornes M, van Dongen-Lases E, Grankvist K, Ibarz M, Kristensen G, Lippi G, et al. Order of blood draw: opinion paper by the European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE). Clin Chem Lab Med 2017;55:27–31.Web of ScienceCrossrefGoogle Scholar

  • 8.

    Banfi G, Salvagno GL, Lippi G. The role of ethylenediamine tetraacetic acid (EDTA) as in vitro anticoagulant for diagnostic purposes. Clin Chem Lab Med 2007;45:565–76.PubMedGoogle Scholar

  • 9.

    Lippi G, Favaloro EJ. Preanalytical issues in hemostasis and thrombosis testing. Methods Mol Biol 2017;1646:29–42.CrossrefPubMedGoogle Scholar

  • 10.

    Lippi G, von Meyer A, Cadamuro J, Simundic AM. Blood sample quality. Diagnosis (Berl) 2019;6:25–31.PubMedGoogle Scholar

  • 11.

    Lippi G, Salvagno GL, Brocco G, Gelati M, Danese E, Favaloro EJ. Impact of experimental hypercalcemia on routine haemostasis testing. PLoS One 2017;12:e0175094.CrossrefPubMedWeb of ScienceGoogle Scholar

  • 12.

    Lippi G, Salvagno GL, Adcock DM, Gelati M, Guidi GC,Favaloro EJ. Right or wrong sample received for coagulation testing? Tentative algorithms for detection of an incorrect type of sample. Int J Lab Hematol 2010;32:132–8.PubMedCrossrefWeb of ScienceGoogle Scholar

  • 13.

    Smith JC Jr, Lewis S, Holbrook J, Seidel K, Rose A. Effect of heparin and citrate on measured concentrations of various analytes in plasma. Clin Chem 1987;33:814–6.PubMedGoogle Scholar

  • 14.

    Cerón JJ, Martínez-Subiela S, Hennemann C, Tecles F. The effects of different anticoagulants on routine canine plasma biochemistry. Vet J 2004;167:294–301.PubMedCrossrefGoogle Scholar

  • 15.

    Mohri M, Rezapoor H. Effects of heparin, citrate, and EDTA on plasma biochemistry of sheep: comparison with serum. Res Vet Sci 2009;86:111–4.CrossrefWeb of SciencePubMedGoogle Scholar

  • 16.

    van den Besselaar AM, van Zanten AP, Brantjes HM, Elisen MG, van der Meer FJ, Poland DC, et al. Comparative study of blood collection tubes and thromboplastin reagents for correction of INR discrepancies: a proposal for maximum allowable magnesium contamination in sodium citrate anticoagulant solutions. Am J Clin Pathol 2012;138:248–54.Web of SciencePubMedCrossrefGoogle Scholar

  • 17.

    Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Picheth G, Guidi GC. Preanalytical management: serum vacuum tubes validation for routine clinical chemistry. Biochem Med (Zagreb) 2012;22:180–6.PubMedGoogle Scholar

  • 18.

    Plebani M, Graziani MS, Tate JR. Harmonization in laboratory medicine: blowin’ in the wind. Clin Chem Lab Med 2018;56:1559–62.Web of SciencePubMedCrossrefGoogle Scholar

  • 19.

    Lippi G, Plebani M. Opportunities and drawbacks of nonstandard body fluid analysis. Clin Chem Lab Med 2017;55:907–9.PubMedWeb of ScienceGoogle Scholar

About the article

Corresponding author: Prof. Giuseppe Lippi, Section of Clinical Biochemistry, University Hospital of Verona, Piazzale LA Scuro, 37134 Verona, Italy

aDavide Demonte and Mairi Pucci contributed equally to this work.


Received: 2019-03-29

Accepted: 2019-04-18

Published Online: 2019-05-04


Author contributions: All the authors have accepted responsibility for the entire content of this submitted manuscript and approved submission.

Research funding: None declared.

Employment or leadership: None declared.

Honorarium: None declared.

Competing interests: The funding organization(s) played no role in the study design; in the collection, analysis, and interpretation of data; in the writing of the report; or in the decision to submit the report for publication.


Citation Information: Diagnosis, 20190027, ISSN (Online) 2194-802X, ISSN (Print) 2194-8011, DOI: https://doi.org/10.1515/dx-2019-0027.

Export Citation

©2019 Walter de Gruyter GmbH, Berlin/Boston.Get Permission

Comments (0)

Please log in or register to comment.
Log in