Alternative Energetics DC Microgrid With Hydrogen Energy Storage System

Genadijs Zaļeskis / Ingars Steiks
Published Online: 2017-01-18 | DOI: https://doi.org/10.1515/ecce-2016-0008

Abstract

This paper is related to an alternative energetics microgrid with a wind generator and a hydrogen energy storage system. The main aim of this research is the development of solutions for effective use of the wind generators in alternative energetics devices, at the same time providing uninterrupted power supply of the critical loads. In this research, it was accepted that the alternative energetics microgrid operates in an autonomous mode and the connection to the conventional power grid is not used. In the case when wind speed is low, the necessary power is provided by the energy storage system, which includes a fuel cell and a tank with stored hydrogen. The theoretical analysis of the storage system operation is made. The possible usage time of the stored hydrogen depends on the available amount of hydrogen and the consumption of the hydrogen by the fuel cell. The consumption, in turn, depends on used fuel cell power. The experimental results suggest that if the wind generator can provide only a part of the needed power, the abiding power can be provided by the fuel cell. In this case, a load filter is necessary to decrease the fuel cell current pulsations.

Keywords: DC-DC power converters; Energy resources; Energy storage; Fuel cells; Renewable energy sources; Uninterruptable power systems; Wind energy

References

  • [1] Latvijas Republikas Vides aizsardzības un reģionālās attīstības Ministrija, “Atjaunojamo energoresursu izmantošanas pamatnostādnes 2006.–2013. gadam (informativa dala),” Rīga, 2006.Google Scholar

  • [2] A. Adamovičs, V. Dubrovskis, I. Plūme, Ā. Jansons, D. Lazdiņa and A. Lazdiņš, Biomasas izmantošanas ilgstspējības kritēriju pielietošana un pasākumu izstrāde, Rīga, 2009.Google Scholar

  • [3] K. Bunker, S. Doig, K. Hawley, and J. Morris, “Renewable Microgrids: Profiles From Islands and Remote Communities Across the Globe,” 2015.Google Scholar

  • [4] The Microgrids Group at Berkeley Lab, “About Microgrids.” [Online]. Available: https://building-microgrid.lbl.gov/about-microgrids-0.

  • [5] H. S. Kumar, “Smart microgrid.” 2015.Google Scholar

  • [6] The Microgrids Group at Berkeley Lab, “Microgrid Definitions.” [Online]. Available: https://building-microgrid.lbl.gov/about-microgrids-0.

  • [7] T. Roughan, “Workshop on Microgrid Technologies and Applications,” RPI Cent. Futur. Energy Syst. Overv., p. 11, 2013.Google Scholar

  • [8] R. W. De Doncker, “Future DC Grid Technology for more Decentralized Power Production and Renewable Power Supplies,” IEEE PEDG2012, 2012.Google Scholar

  • [9] A. Graillot, “Hybrid Micro Grids for rural electrification: Developing Appropriate Technology,” presented at AIE Event, Maputo, 2009.Google Scholar

  • [10] A. Suzdalenko, “Research and Development of Control Means for Intelligent Household Electrical Grids,” Ph.D. Thesis, Riga Technical University, 2013.Google Scholar

  • [11] “MED-Solar Training Course. Module 2. Microgrid Elements,” Universitat Politecnica de Catalunya, p. 59.Google Scholar

  • [12] R. Villafáfila Robles, “Microgrids and emulation of distribution energy resources,” p. 13.Google Scholar

  • [13] P. Karlsson, “DC Distributed Power Systems,” Ph.D. Thesis, Lund University, 2002.Google Scholar

  • [14] D. Deaconu, A. Chirila, M. Albu and L. Toma, “Studies on a LV DC network,” in 2007 European Conference on Power Electronics and Applications, 2007, pp. 1–7. https://doi.org/10.1109/EPE.2007.4417634Crossref

  • [15] A. Sannino, G. Postiglione and M. H. J. Bollen, “Feasibility of a DC network for commercial facilities,” IEEE Trans. Ind. Appl., vol. 39, no. 5, pp. 1499–1507, 2003. https://doi.org/10.1109/TIA.2003.816517Crossref

  • [16] D. J. Hammerstrom, “AC versus DC distribution systems-did we get it right?,” in 2007 IEEE Power Eng. Soc. Gen. Meet. PES, Tampa, FL, pp. 1–5, 2007. https://doi.org/10.1109/PES.2007.386130Crossref

  • [17] A. Kwasinski, “Micro-grids architectures, stability and protections,” 2012.Google Scholar

  • [18] S. Rolland and G. Glania, “Hybrid Mini-Grids for Rural Electrification: Lessons Learned”, CA: Renewable Energy House, Brussels, 2011, 72 p.Google Scholar

  • [19] A. Senfelds, M. Vorobjovs, D. Meike and O. Bormanis, “Power Smoothing Approach within Industrial DC Microgrid with Supercapacitor Storage for Robotic Manufacturing Application,” in 2015 IEEE Int. Conf. on Automation Science and Eng. (CASE), Gothenburg, 2015, vol. 1020, pp. 1333–1338. https://doi.org/10.1109/CoASE.2015.7294283Crossref

  • [20] National Renewable Energy Laboratory, “Power Purchase Agreement Checklist for State and Local Governments,” Golden, Colorado, 2009.Google Scholar

  • [21] M. A. Maehlum, “What’s the Difference Between Net Metering and Feed-In Tariffs?,” Energy Informative, 2014. [Online]. Available: http://energyinformative.org/net-metering-feed-in-tariffs-difference

  • [22] G. Zaleskis and I. Rankis, “Problem of an Estimation of the Wind Generators Economic Efficiency in Latvia,” in Proceedings of the 20th International Conference ELECTRONICS 2016, Palanga, Lithuania, 2016, pp. 16–21.Google Scholar

  • [23] E. H. Camm, M. R. Behnke, O. Bolado et al., “Characteristics of Wind Turbine Generators for Wind Power Plants,” in 2009 IEEE Power & Energy Society General Meeting, Calgary, AB, 2009, pp. 1–5. https://doi.org/10.1109/pes.2009.5275330Crossref

  • [24] P. Suskis, “DC/DC Voltage H-Bridge Converter with Fuzzy Logic Control for Autonomous Power Supply,” in 54th Int. Scientific Conf. of Riga Technical University, Riga, Latvia, 2013.Google Scholar

  • [25] P. Suskis, A. Andreiciks, I. Steiks, O. Krievs and J. Kleperis, “Microgrid for one side wind-and-hydrogen powered generation,” Latvian Journal of Physics and Technical Sciences, no. 1, pp. 12–20, 2014.Google Scholar

  • [26] I. Galkins and O. Tetervenoks, “Efficiency considerations for non-inverting buck-boost converter operating with direct current control,” in 2014 16th European Conf. on Power Electronics and Applicat., Lappeenranta, 2014, pp. 1–8. https://doi.org/10.1109/EPE.2014.6911032Crossref

  • [27] O. Tetervenoks and I. Galkins, “Considerations on practical implementation of control system for switch mode current regulator,” in 2014 14th Biennial Baltic Electronic Conference (BEC), Tallinn, 2014, pp. 225–228. https://doi.org/10.1109/bec.2014.7320597Crossref

  • [28] D. Connolly, “A Review of Energy Storage Technologies for the Integration of Fluctuating Renewable Energy,” University of Limerick, 2009, 46 p.Google Scholar

  • [29] I. Steiks, “Ūdeņraža enerģētiskās iekārtas spēka elektronikas pārveidotāju izstrāde.” Promocijas darbs, Rīgas Tehniskā universitāte, Rīga, 2011, 146 p.Google Scholar

  • [30] G. Zaleskis, I. Steiks, A. Pumpurs and O. Krievs, “DC-AC Converter for Load Supply in Autonomous Wind-Hydrogen Power System” in 56th Int. Scientific Conf. on Power and Electrical Engineering of Riga Technical University (RTUCON), Riga, Latvia, 2015, pp. 169–173. https://doi.org/10.1109/RTUCON.2015.7343118Crossref

  • [31] HyPM® Fuel Cell Power Modules, Hydrogenics, advanced hydrogen solutions. [Online]. Available: www.hydrogenics.com.

  • [32] Hy PM XR8 Installation, Operation and Maintenance Manual, Revision 2, DOC. P/N:1035409-02, Hydrogenics, Aug. 2010.Google Scholar

About the article

Published Online: 2017-01-18

Published in Print: 2016-12-01


Citation Information: Electrical, Control and Communication Engineering, ISSN (Online) 2255-9159, DOI: https://doi.org/10.1515/ecce-2016-0008.

Export Citation

© 2016 Riga Technical University. This work is licensed under the Creative Commons Attribution 4.0 Public License. BY 4.0