Editorial Board: Daniel, Geoffrey / Militz, Holger / Rosenau, Thomas / Sixta, Herbert / Vuorinen, Tapani / Argyropoulos, Dimitris S. / Balakshin, Yu / Barnett, J. R. / Burgert, Ingo / Rio, Jose C. / Evans, Robert / Evtuguin, Dmitry V. / Frazier, Charles E. / Fukushima, Kazuhiko / Gindl-Altmutter, Wolfgang / Glasser, W. G. / Holmbom, Bjarne / Isogai, Akira / Kadla, John F. / Koch, Gerald / Lachenal, Dominique / Laine, Christiane / Mansfield, Shawn D. / Morrell, J.J. / Niemz, Peter / Potthast, Antje / Ragauskas, Arthur J. / Ralph, John / Rice, Robert W. / Salin, Jarl-Gunnar / Schmitt, Uwe / Schultz, Tor P. / Sipilä, Jussi / Takano, Toshiyuki / Tamminen, Tarja / Theliander, Hans / Welling, Johannes / Willför, Stefan / Yoshihara, Hiroshi

12 Issues per year


IMPACT FACTOR 2017: 2.079

CiteScore 2017: 1.94

SCImago Journal Rank (SJR) 2017: 0.709
Source Normalized Impact per Paper (SNIP) 2017: 0.979

Online
ISSN
1437-434X
See all formats and pricing
More options …
Volume 67, Issue 1

Issues

Effects of climatic test parameters on acetic acid emission from beech (Fagus sylvatica L.)

Vera Steckel
  • Thünen-Institut für Holztechnologie und Holzbiologie, Leuschnerstraße 91c, 21031 Hamburg, Germany
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Anna Knöpfle / Martin Ohlmeyer
  • Corresponding author
  • Thünen-Institut für Holztechnologie und Holzbiologie, Leuschnerstraße 91c, 21031 Hamburg, Germany
  • Email
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2012-09-10 | DOI: https://doi.org/10.1515/hf-2011-0237

Abstract

Acetic acid (AA) emission from beech samples was studied in test chambers operated according to ISO 16000 part 9 and as a function of temperature and relative humidity (RH). The impact of RH was higher than that of temperature. AA emission was about 45% higher at 75% RH than under standard parameters (50% RH, 23°C). Probably, RH influences AA emission both by enhanced hydrolysis of acetyl groups, as well as by facilitating the release of AA into the surrounding air by diffusion. The concentration of AA in test chamber air was determined with thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) as well as with ion chromatography (IC). Both techniques provided similar results. The values measured by IC ranged constantly 15% below those obtained with TD-GC-MS. This can be ascribed to losses during sampling of test chamber air.

Keywords: acetic acid emission; beech; ion chromatography (IC); testing parameters of VOCs; thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS)

About the article

Corresponding author. Thünen-Institut für Holztechnologie und Holzbiologie, Leuschnerstraße 91c, 21031 Hamburg, Germany


Received: 2011-11-25

Accepted: 2012-07-30

Published Online: 2012-09-10

Published in Print: 2013-01-01


Citation Information: , Volume 67, Issue 1, Pages 47–51, ISSN (Online) 1437-434X, ISSN (Print) 0018-3830, DOI: https://doi.org/10.1515/hf-2011-0237.

Export Citation

©2013 by Walter de Gruyter Berlin Boston.Get Permission

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
A. Mozaffar, N. Schoon, A. Bachy, A. Digrado, B. Heinesch, M. Aubinet, M.-L. Fauconnier, P. Delaplace, P. du Jardin, and C. Amelynck
Atmospheric Environment, 2017
[2]
Sebastian Seibold, Claus Bässler, Roland Brandl, Boris Büche, Alexander Szallies, Simon Thorn, Michael D. Ulyshen, Jörg Müller, and Christopher Baraloto
Journal of Applied Ecology, 2016, Volume 53, Number 3, Page 934

Comments (0)

Please log in or register to comment.
Log in