Use of CFD for Wastewater Disinfection Process Analysis: E.coli Inactivation with Peroxyacetic Acid (PAA)

Domenico Santoro / Timothy A. Bartrand / Dennis J. Greene / Bakhtier Farouk / Charles N. Haas / Michele Notarnicola / Lorenzo Liberti
Published Online: 2005-11-03 | DOI: https://doi.org/10.2202/1542-6580.1283

Historically, the priority in disinfection reactor design has been microbial inactivation with a high factor of safety, neglecting other processes such as disinfection byproduct (DBP) formation and chemical use minimization. With heightened awareness and regulation of DBPs, advanced chemical engineering principles and practices are being employed in disinfection process analysis and design in order to minimize DBP production while ensuring sufficient microbial inactivation. Computational fluid dynamics (CFD) is increasingly popular as a tool to evaluate reactor performance and assess design concepts. This study presents the results of CFD analyses of two disinfection reactors with very different aspect ratios and design, but being characterized by the same theoretical hydraulic residence time (i.e., 30 minutes). Both reactors were used to inactivate E. coli with the novel disinfectant peroxyacetic acid (PAA). CFD calculations were performed for inactivation of E. coli (10000 CFU/100 mL) with PAA concentrations of 4 and 8 mg/L. Calculations were carried out for two serpentine reactors with aspect ratios (channel width to water depth) of 2:1 and 1:3. In the second reactor, perforated baffle plates were placed at the end of each channel in an attempt to promote uniform flow. Both reactors achieved adequate removal of organisms, but displayed non-ideal hydrodynamics, with significant recirculation regions that reduced the volume available for reaction and promoted short-circuiting. CFD simulations emphasized that reactor hydrodynamics impacts on the specific disinfection performances inducing different ratio of reactor volume active during the disinfection process.

Keywords: E. coli Inactivation; CFD; Wastewater Disinfection

About the article

Published Online: 2005-11-03

Citation Information: International Journal of Chemical Reactor Engineering, Volume 3, Issue 1, ISSN (Online) 1542-6580, DOI: https://doi.org/10.2202/1542-6580.1283.

Export Citation

©2011 Walter de Gruyter GmbH & Co. KG, Berlin/Boston. Copyright Clearance Center

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

Domenico Santoro, Ferdinando Crapulli, Mehrdad Raisee, Giuseppe Raspa, and Charles N. Haas
Environmental Science & Technology, 2015, Volume 49, Number 12, Page 7265
Timothy A. Bartrand, Bakhtier Farouk, and Charles N. Haas
International Journal of Multiphase Flow, 2009, Volume 35, Number 2, Page 171