Jump to ContentJump to Main Navigation
Show Summary Details
More options …

International Journal of Emerging Electric Power Systems

Editor-in-Chief: Sidhu, Tarlochan

Ed. by Khaparde, S A / Rosolowski, Eugeniusz / Saha, Tapan K / Gao, Fei


CiteScore 2018: 0.86

SCImago Journal Rank (SJR) 2018: 0.220
Source Normalized Impact per Paper (SNIP) 2018: 0.430

Online
ISSN
1553-779X
See all formats and pricing
More options …
Volume 15, Issue 1

Issues

Design and Digital Implementation of Constant Frequency Hysteresis Current Controller for Three-Phase Voltage Source Inverter Using TMS320F2812

D. Kalyanraj
  • Corresponding author
  • Electrical and Electronics Engineering, Saranathan College of Engineering, Trichirappalli, Tamilnadu 620012, India
  • Email
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ S. Lenin Prakash
  • Electrical and Electronics Engineering, Saranathan College of Engineering, Trichirappalli, Tamilnadu 620012, India
  • Email
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2014-01-18 | DOI: https://doi.org/10.1515/ijeeps-2013-0141

Abstract

A constant frequency hysteresis current control technique for a three-phase voltage source inverter (VSI) has been developed for AC drives, power quality and renewable energy applications. This paper presents a digital implementation of a constant frequency hysteresis current control technique for a three-phase VSI feeding an inductive load, using digital signal controller TMS320F2812. The limitations of variable frequency hysteresis control have been discussed and overcoming these limitations by means of digital implementation has been proposed. The complete design procedure of the proposed technique has been presented with an illustrative example. The three-phase VSI feeding an inductive load has also been simulated by using MATLAB and the simulation results have been presented. The hardware results of hysteresis current controlled three-phase VSI feeding an inductive load have been presented. Also the performance analysis of the hysteresis current controller has been presented. Operation of this controller has also been explained with a help of phase plane trajectory of hysteresis controller.

Keywords: constant frequency; current control; digital control; hysteresis control

References

  • 1.

    Kazmierkowski MP, Malesani L. Current control techniquesfor three phase voltage source PWM converters. IEEE Trans Ind Electron 1998;45:691–703.CrossrefGoogle Scholar

  • 2.

    Brod DM, Novonty DW. Current control of VSI pwm inverters. IEEE Trans Ind Appl 1985;21:562–70.CrossrefGoogle Scholar

  • 3.

    Ho CV, Cheung VS, Chung S-H. Constant frequency hysteresis control of grid connected VSI without bandwidth control. IEEE Trans Power Electron 2009;24:2484–95.Web of ScienceCrossrefGoogle Scholar

  • 4.

    Zheng Q, Chang L. Study of advanced current control strategies for three phase grid connected PWM inverters for distributed generation. IEEE conference on control applications, Canada, August28–31,2005.Google Scholar

  • 5.

    Dixon J, Tepper S, Moran L. Practical evaluation ofdifferent modulation techniques for current controlledvoltage source inverter. IEE Proc Electr Power Appl 1996;143:301–6.CrossrefGoogle Scholar

About the article

Published Online: 2014-01-18


Citation Information: International Journal of Emerging Electric Power Systems, Volume 15, Issue 1, Pages 13–23, ISSN (Online) 1553-779X, ISSN (Print) 2194-5756, DOI: https://doi.org/10.1515/ijeeps-2013-0141.

Export Citation

©2014 by Walter de Gruyter Berlin / Boston.Get Permission

Comments (0)

Please log in or register to comment.
Log in