Examiner’s finger-mounted fetal tissue oximetry: a preliminary report on 30 cases

Toshiyuki Uchida / Naohiro Kanayama / Mari Mukai / Naomi Furuta / Hiroaki Itoh / Hikaru Suzuki / Masatsugu Niwayama
  • Department of Electrical and Electronics Engineering, Shizuoka University, Japan
  • Research Institute of Electronics, Shizuoka University, Japan
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2015-03-09 | DOI: https://doi.org/10.1515/jpm-2014-0297

Abstract

Objective:

To describe preliminary experience with a finger-mounted fetal tissue oximetry probe during the 2nd stage of labor.

Materials and methods:

A total of 30 term pregnant women without pregnancy complications were recruited. We measured fetal tissue oxygen saturation (FtO2) by using a finger-mounted fetal tissue oximetry during cervical examinations in the 2nd stage of labor. The data capturing rate of FtO2 and the interclass correlation coefficient were also examined. The mean FtO2 was compared to the neonatal condition assessed by the levels of umbilical cord blood.

Results:

FtO2 was obtained in all cases, regardless of wetness, hair color, the part of the fetal head that was exposed, rotation of the fetus, color of amniotic fluid, and caput succedaneum. The mean FtO2 was 65.5%±8.58% in normal neonates [Apgar score >7 (1 min), n=25]. The mean FtO2 was significantly correlated with umbilical cord arterial pH (r=0.52, P=0.0030, n=30), but not with umbilical cord arterial partial pressure of oxygen. The interclass correlation coefficient was 0.94.

Conclusions:

Tissue oxygen saturation of the fetal head was obtained easily by the examiner’s finger-mounted fetal tissue oximetry.

Keywords: Examiner; fetal tissue oximetry; fetal tissue oxygen saturation; finger pulp; near-infrared spectroscopy; parturition

References

  • [1]

    Signore C, Freeman RK, Spong CY. Antenatal testing – a reevaluation: executive summary of a Eunice Kennedy Shriver National Institute of Child Health and Human Development workshop. Obstet Gynecol. 2009;113:687–701.Google Scholar

  • [2]

    Langer B, Carbonne B, Goffinet F, Le Gouëff F, Berkane N, Laville M. Fetal pulse oximetry and fetal heart rate monitoring during stage II of labour. Eur J Obstet Gynecol Reprod Biol. 1997;72:S57–61.Google Scholar

  • [3]

    Arikan GM, Haeusler MC, Deutsch MT, Greimel ER, Dorfer M. Maternal perceptions of labor with fetal monitoring by pulse oximetry in a research setting. Birth. 1998;25:182–9.Google Scholar

  • [4]

    Garite TJ, Dildy GA, McNamara H, Nageotte MP, Boehm FH, Dellinger EH, et al. A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns. Am J Obstet Gynecol. 2000;183:1049–58.Google Scholar

  • [5]

    Colditz PB, Begg L, East CE. Fetal pulse oximetry. Instrumentation and recent clinical experience. Clin Perinatol. 1999;26:869–80.Google Scholar

  • [6]

    Knitza R, Rall G, Schaller N, Kolben M. First results of a pilot study with the FetalSAT fetal pulse oximetry system. Geburtshilfe Frauenheilkd. 2004;64:600–5.Google Scholar

  • [7]

    East CE, Begg L, Colditz PB, Lau R. Fetal pulse oximetry for fetal assessment in labour. Cochrane Database Syst Rev. 2014;10:CD004075.Google Scholar

  • [8]

    van Oudgaarden E, Johnson N. Clinical value of antenatal fetal pulse oximetry. J Perinat Med. 1994;22:295–300.Google Scholar

  • [9]

    Dildy GA, van den Berg PP, Katz M, Clark SL, Jongsma HW, Nijhuis JG, et al. Intrapartum fetal pulse oximetry: fetal oxygen saturation trends during labor and relation to delivery outcome. Am J Obstet Gynecol. 1994;171:679–84.Google Scholar

  • [10]

    Dildy GA. Fetal pulse oximetry. Clin Obstet Gynecol. 2011;54:66–73.Google Scholar

  • [11]

    Aldrich CJ, D’Antona D, Wyatt JS, Spencer JA, Peebles DM, Reynolds EO. Fetal cerebral oxygenation measured by near-infrared spectroscopy shortly before birth and acid-base status at birth. Obstet Gynecol. 1994;84:861–6.Google Scholar

  • [12]

    Schmidt S. Laserspectroscopy in the fetus during labour. Eur J Obstet Gynecol Reprod Biol. 2003;110:S127–31.Google Scholar

  • [13]

    East CE. Chan FY, Colditz P.B, Begg LM. Fetal pulse oximetry for fetal assessment in labour. Cochrane Database Syst Rev. 2007;2:CD004075.Google Scholar

  • [14]

    Kanayama N, Niwayama M. Examiner’s finger-mounted fetal tissue oximetry. J Biomed Opt. 2014;19:1–5.Google Scholar

  • [15]

    Amano K, Hirano S, Nishijima M. Significance of fetal arterial oxygen saturation (SpO2) monitoring. Nihon Sanka Fujinka Gakkai Zasshi. 1996;48:96–102.Google Scholar

  • [16]

    Pichler G, Binder C, Avian A, Beckenbach E, Schmolzer GM, Urlesberger B. Reference ranges for regional cerebral tissue oxygen saturation and fractional oxygen extraction in neonates during immediate transition after birth. J Pediatr. 2013;163:1558–63.Google Scholar

  • [17]

    Fouzas S, Priftis KN, Anthoracopoulos MB. Pulse oximetry in pediatric practice. Pediatrics. 2011;128:740–52.Google Scholar

About the article

Corresponding author: Naohiro Kanayama, MD, PhD, Department of Obstetrics and Gynecology, Hamamatsu University School of Medicine, 1-20-1 Handa-yama, Hamamatsu 431-3192, Japan, Tel.: +81-453-435-2309, Fax: +81-453-435-2308, E-mail:


Received: 2014-09-04

Accepted: 2015-02-10

Published Online: 2015-03-09

Published in Print: 2016-10-01


The authors stated that there are no conflicts of interest regarding the publication of this article.


Citation Information: Journal of Perinatal Medicine, Volume 44, Issue 7, Pages 745–749, ISSN (Online) 1619-3997, ISSN (Print) 0300-5577, DOI: https://doi.org/10.1515/jpm-2014-0297.

Export Citation

©2016 Walter de Gruyter GmbH, Berlin/Boston.Get Permission

Citing Articles

Here you can find all Crossref-listed publications in which this article is cited. If you would like to receive automatic email messages as soon as this article is cited in other publications, simply activate the “Citation Alert” on the top of this page.

[1]
Toshiyuki Uchida, Naohiro Kanayama, Kenta Kawai, and Masatsugu Niwayama
Journal of Biomedical Optics, 2016, Volume 21, Number 4, Page 040502
[2]
Keisuke Hiwatashi, Kimiaki Doi, Risuke Mizuno, and Makoto Yokosuka
Journal of Biomedical Optics, 2017, Volume 22, Number 2, Page 026006
[3]
Gerard Cummins, Jessica Kremer, Anne Bernassau, Andrew Brown, Helen Bridle, Holger Schulze, Till Bachmann, Michael Crichton, Fiona Denison, and Marc Desmulliez
Sensors, 2018, Volume 18, Number 8, Page 2648
[4]
Toshiyuki Uchida, Naohiro Kanayama, Kenta Kawai, Mari Mukai, Kazunao Suzuki, Hiroaki Itoh, and Masatsugu Niwayama
Journal of Obstetrics and Gynaecology Research, 2018
[5]
Mari Mukai, Toshiyuki Uchida, Hiroaki Itoh, Hikaru Suzuki, Masatsugu Niwayama, and Naohiro Kanayama
Journal of Obstetrics and Gynaecology Research, 2017, Volume 43, Number 5, Page 855

Comments (0)

Please log in or register to comment.
Log in