A study about the measurement method of the homogeneity of radioactivity along an iridium-192 wire used in brachytherapy

Osvaldo L. Costa
  • Corresponding author
  • Nuclear and Energy Research Institute (IPEN/CNEN-SP), Radiation Technology Center CTR), 2242 Prof. Lineu Prestes Ave.,05508-000, São Paulo, SP, Brazil, Tel.: +55 11 3133 9821, Fax: +55 11 3133 9765,
  • Email
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Wilson A. P. Calvo
  • Nuclear and Energy Research Institute (IPEN/CNEN-SP), Radiation Technology Center CTR), 2242 Prof. Lineu Prestes Ave.,05508-000, São Paulo, SP, Brazil, Tel.: +55 11 3133 9821, Fax: +55 11 3133 9765,
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Carlos A. Zeituni
  • Nuclear and Energy Research Institute (IPEN/CNEN-SP), Radiation Technology Center CTR), 2242 Prof. Lineu Prestes Ave.,05508-000, São Paulo, SP, Brazil, Tel.: +55 11 3133 9821, Fax: +55 11 3133 9765,
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Maria E. C. M. Rostelato
  • Nuclear and Energy Research Institute (IPEN/CNEN-SP), Radiation Technology Center CTR), 2242 Prof. Lineu Prestes Ave.,05508-000, São Paulo, SP, Brazil, Tel.: +55 11 3133 9821, Fax: +55 11 3133 9765,
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ João A. Moura
  • Nuclear and Energy Research Institute (IPEN/CNEN-SP), Radiation Technology Center CTR), 2242 Prof. Lineu Prestes Ave.,05508-000, São Paulo, SP, Brazil, Tel.: +55 11 3133 9821, Fax: +55 11 3133 9765,
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Anselmo Feher
  • Nuclear and Energy Research Institute (IPEN/CNEN-SP), Radiation Technology Center CTR), 2242 Prof. Lineu Prestes Ave.,05508-000, São Paulo, SP, Brazil, Tel.: +55 11 3133 9821, Fax: +55 11 3133 9765,
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Carla D. Souza
  • Nuclear and Energy Research Institute (IPEN/CNEN-SP), Radiation Technology Center CTR), 2242 Prof. Lineu Prestes Ave.,05508-000, São Paulo, SP, Brazil, Tel.: +55 11 3133 9821, Fax: +55 11 3133 9765,
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Samir L. Somessari
  • Nuclear and Energy Research Institute (IPEN/CNEN-SP), Radiation Technology Center CTR), 2242 Prof. Lineu Prestes Ave.,05508-000, São Paulo, SP, Brazil, Tel.: +55 11 3133 9821, Fax: +55 11 3133 9765,
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2014-03-25 | DOI: https://doi.org/10.2478/nuka-2014-0003

Abstract

The Nuclear and Energy Research Institute has produced, since 1998, iridium-192 wires used in low dose rate brachytherapy. In the paper the authors studied the influence of wire profile on the homogeneity distribution of radioactivity of iridium-192 along the wire. The authors propose the improvements in the quality control procedure that will provide more accurate measurement data and suggest changes in control devices.

Keywords : iridium-192; iridium wire; low dose rate brachytherapy; quality control; cancer treatment; radioactive sources production

References

  • 1. Aird, E. G., Williams, J. R., & Rembowska, A. (2000).Brachytherapy. In J. R. Williams, & D. I. Thwaites (Eds.), Radiotherapy physics in practice (2nd ed., pp. 187-226).Oxford: Oxford University Press.Google Scholar

  • 2. Khan, F. M. (1994). The physics of radiation therapy.Baltimore: Williams & Wilkins.Google Scholar

  • 3. Rostelato, M. E. C. M. (1997). Preparação de fontes de irídio-192 para uso em braquiterapia. Unpublished master’s thesis, Nuclear and Energy Research Institute, São Paulo, BrazilGoogle Scholar

  • 4. Rostelato, M. E. C. M., Rela, P. R., Zeituni, C. A., Feher, A., Manzoli, J. E., Moura, J. A., Moura, E. S., & Silva, C.P. G. (2008). Development and production of radioactive sources used for cancer treatment in Brazil. Nukleonika, 53(S2), S99-S103.Google Scholar

  • 5. McSherry, A. (2013, August 12). Calculus Tools for Android (Version 1.2.1) [Software]. Retrieved from http://market.android.com/details?id=com.andymc.derivative&feature=search_result.Google Scholar

About the article

Published Online: 2014-03-25

Published in Print: 2014-03-01


Citation Information: Nukleonika, Volume 59, Issue 1, Pages 37–39, ISSN (Online) 0029-5922, DOI: https://doi.org/10.2478/nuka-2014-0003.

Export Citation

This content is open access.

Comments (0)

Please log in or register to comment.
Log in