Jump to ContentJump to Main Navigation
Show Summary Details
More options …

Seminars in Cardiovascular Medicine

The Journal of Lithuanian Heart Association

1 Issue per year

Open Access
Online
ISSN
1822-7767
See all formats and pricing
More options …

The role of real time three-dimensional transoesophageal echocardiography in acquired mitral valve disease

Agnė Drąsutienė
  • Corresponding author
  • Centre of Cardiology and Angiology, Vilnius University Hospital Santariškių Klinikos, Santariškių 2, Vilnius, Lithuania
  • Email
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Sigita Aidietienė
  • Centre of Cardiology and Angiology, Vilnius University Hospital Santariškių Klinikos, Vilnius, Lithuania
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
/ Diana Zakarkaitė
  • Centre of Cardiology and Angiology, Vilnius University Hospital Santariškių Klinikos, Vilnius, Lithuania
  • Other articles by this author:
  • De Gruyter OnlineGoogle Scholar
Published Online: 2016-03-05 | DOI: https://doi.org/10.2478/semcard-2015-0003

Summary

Real time (RT) three-dimensional (3D) imaging is one of the most significant developments of the last decade and is now being used with increasing frequency in echocardiography and interventional cardiology laboratories. Improvements in transducer technologies and the development of a matrix array transducer were the most important achievements that lead to the new era of real time 3D transoesophageal echocardiography (TEE). RT 3D TEE is ideal for assessing the mitral valve (MV) because of its high spatial resolution altering in improved MV anatomic detail. This imaging modality provides images of high quality which is of a great clinical value inmaking diagnosis of MV disease and a valuable tool for surgeons and interventional cardiologists in planning and guiding interventional procedures. This review is intended to provide data about normal MV anatomy and clinical usefulness of RT 3D TEE in defining acquired MV pathology.

Keywords : transoesophageal echocardiography; mitral valve

References

  • [1] Vahanian A, Alfieri O, Andreotti F, Antunes MJ, Barón-Esquivias G, Baumgartner H, et al. Guidelines on the management of valvular heart disease. Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) 1; European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J 2012 Oct;33(19):2451-96.Google Scholar

  • [2] Von Ramm OT, Smith SW. Real time volumetric ultrasound imaging system. J Digit Imaging 1990;3:261-6.CrossrefGoogle Scholar

  • [3] Sheikh K, Smith SW, von Ramm OT, Kisslo J. Real-time, three-dimensional echocardiography: feasibility and initial use. Echocardiography 1991;8:119-25.CrossrefGoogle Scholar

  • [4] Yang HS, Bansal RC, Mookadam F. Practical guide for three-dimensional transthoracic echocardiography using a fully sampled matrix array transducer. Jam Soc Echocardiogr 2008;21:979-89.CrossrefGoogle Scholar

  • [5] Flachskampf FA, Badano L, Daniel WG, Feneck RO, Fox KF, et al. Recommendations for transoesophageal echocardiography: update 2010. Eur J Echocardiogr 2010;11:557-76.CrossrefGoogle Scholar

  • [6] Lang R, Badano L, Tsang W. EAE/ASE recommendations for image acquisition and display using three-dimensional echocardiography. J Am Soc Echocardiogr 2012;25:3-46.CrossrefGoogle Scholar

  • [7] Salcedo E, Quaife R, Seres T, Carrol J. A framework for systematic characterization of the mitral valve by real time three dimensional transesopfageal echocardiography. J Am Soc Echocardiogr 2009;22:1087-99.CrossrefWeb of ScienceGoogle Scholar

  • [8] Barlow JB. Perspectives on the mitral valve. Philadelphia, Pa: F.A. Davis; 1987.Google Scholar

  • [9] Van Mieghem N, Piazza N, Anderson R, Tzikas A, Nieman K, et al. Anatomy of the mitral valvular complex and its implications for transcatheter interventions for mitral regurgitation. J Am Coll Cardiol 2010;56:617-26.Web of ScienceCrossrefGoogle Scholar

  • [10] Carpentier A. Cardiac valve surgery: the ‘French correction’. Journal of Thoracic and Cardiovascular Surgery 1983;86(3):323-37.Google Scholar

  • [11] Kumar N, Kumar M, Duran CMG. A revised terminologyfor recording surgical-findings of the mitral valve. Journal of Heart Valve Disease 1995;4(1):70-5.Google Scholar

  • [12] Silbiger JJ, Bazaz R. Contemporary insights into the functional anatomy of the mitral valve. Am Hear J 2009;158(6):887-95.CrossrefGoogle Scholar

  • [13] Nkomo VT, Gardin JM, Skelton TN, Gottdiener JS, et al. Burden of valvular heart disease: a population based study. Lancet 2006;368:1005-11.CrossrefGoogle Scholar

  • [14] Lung B, Baron G,Messika-Zeitoun D, Detaint D, Vanoverschelde JL, et al. A prospective survey of patients with valvular heart disease in Europe: the Euro Heart Survey on Valvular Disease. Eur Heart J 2003;24:1231-43.CrossrefGoogle Scholar

  • [15] Chandra S, Salgo I, Sugeng L, Weinert L, Tsang W, et al. Characterization of degenerative mitral valve disease using morphologic analysis of real-time three-dimensional echocardiographic images: objective insight into complexity and planning of mitral valve repair. Circ Cardiovasc Imaging 2011;4:24-32.Google Scholar

  • [16] Filsoufi F, Carpentier A. Principles of reconstructive surgery in degenerative mitral valve disease. Semin Thorac Cardiovasc Surg 2007;19:103-10.CrossrefGoogle Scholar

  • [17] Cotran RS, Kumar V, Collins T. Robbins pathologic base of disease. 6th ed. Philadelphia, Pa: W.B. Saunders Company; 1999. Chapter 13, p. 569-72.Google Scholar

  • [18] Faletra FF, de Castro S, Pandian NG. Atlas of real time 3D transesophageal echocardiography. Berlin: Springer- Verlag; 2010.Google Scholar

  • [19] Pan M, Medina A, Suarez de Lezo J, et al. Factors determining late success after mitral balloon valvulotomy. Am J Cardiol 1993;71(13):1181-5.CrossrefGoogle Scholar

  • [20] Wilkins GT,Weyman AE, Abascal VM, et al. Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation. Br Hear J 1988;60(4):299-308.CrossrefGoogle Scholar

  • [21] Soliman OII, Anwar AM, Metawei AK, McGhie JS, Geleijnse ML, Ten Cate FJ. New scores for the assessment ofmitral stenosis using real-time three-dimensional echocardiography. Curr Cardiovasc Imaging Rep 2011;4:370-7.Google Scholar

  • [22] Sutaria N, Shaw TR, Prendergast B, Northridge D. Transesophageal echocardiographic assessment of mitral valve commissural morphology predicts outcome after balloon mitral valvotomy. Heart 2006;92:52-7.CrossrefGoogle Scholar

  • [23] Carpentier A, Adams D, Filsoufi F. Carpentier’s reconstructive valve surgery. Philadelphia, Pa: Saunders; 2010. p. 116-8.Google Scholar

  • [24] Anwar A, et al. True mitral annulus diameter is underestimated by two dimensional echocardiography as evidenced by real-time three-dimensional echocardiography and magnetic resonance imaging. Int J Cardiovasc Imaging 2007;23:541-7.CrossrefWeb of ScienceGoogle Scholar

  • [25] Ender J, Koncar-Zeh J, Mukherjee C, Jacobs S, Borger MA, et al. Value ofaugmented reality-enhanced transesophageal echocardiography (TEE) for determining optimal annuloplasty ring sizeduring mitral valve repair. Ann Thorac Surg 2008;86:1473-8.CrossrefGoogle Scholar

  • [26] Faletra FF, Moschovitis G, Auricchio A. Visualisation of thrombus formation on prosthetic valve by real-time three-dimensional transoesophageal echocardiography. Heart 2009;95:482.CrossrefGoogle Scholar

  • [27] Kronzon I, Sugeng L, Perk G, Hirsh D, Weinert L, Garcia Fernandez MA, Lang RM. Real-time 3-dimensional transesophageal echocardiography in the evaluation of post-operative mitral annuloplasty ring and prosthetic valve dehiscence. J Am Coll Cardiol 2009;53:1543-7.CrossrefGoogle Scholar

  • [28] Fischer G, Adams D. Real-time three-dimensional TEE guided repair of a paravalvular leak after mitral valve replacement. Eur J Echocardiogr 2008;9:868-9.CrossrefWeb of ScienceGoogle Scholar

  • [29] Biner S, Rafique AM, Kar S, Siegel RJ. Live threedimensional transesophageal echocardiography-guided transcatheter closure of a mitral paraprosthetic leak by Amplatzer occluder. J Am Soc Echocardiogr 2008;21:1282.e7-9.CrossrefGoogle Scholar

  • [30] Faletra F, et al. Role of real-time three dimensional transoesophageal echocardiography as guidance imaging modality during catheter based edge-to-edge mitral valve repair. Heart 2013;0:1-12.Google Scholar

  • [31] Colli A, et al. TEE-guided transapical beating-heart neochord implantation in mitral regurgitation. JACC Cardiovasc Imaging 2014;7(3):322-3.Google Scholar

About the article

Received: 2015-08-21

Accepted: 2015-11-02

Published Online: 2016-03-05

Published in Print: 2015-12-01


Citation Information: Seminars in Cardiovascular Medicine, ISSN (Online) 1822-7767, DOI: https://doi.org/10.2478/semcard-2015-0003.

Export Citation

© by Agnė Drąsutienė. This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License. BY-NC-ND 4.0

Comments (0)

Please log in or register to comment.
Log in