Jump to ContentJump to Main Navigation
Show Summary Details
More options …

tm - Technisches Messen

Plattform für Methoden, Systeme und Anwendungen der Messtechnik

[TM - Technical Measurement: A Platform for Methods, Systems, and Applications of Measurement Technology
]

Editor-in-Chief: Puente León, Fernando / Zagar, Bernhard

12 Issues per year


IMPACT FACTOR 2017: 0.476

CiteScore 2017: 0.46

SCImago Journal Rank (SJR) 2017: 0.239
Source Normalized Impact per Paper (SNIP) 2017: 0.566

Online
ISSN
2196-7113
See all formats and pricing
More options …
Volume 77, Issue 9

Issues

Quadraturinterferometer mit automatischer Fokussierung

Andreas Gollwitzer / Gerhard Fischerauer
Published Online: 2010-09-09 | DOI: https://doi.org/10.1524/teme.2010.0031

Zusammenfassung

Oberflächenschwingungen kleiner Amplitude werden häufig interferometrisch gemessen. Um zusätzlich eine hohe örtliche Auflösung zu erreichen, muss der Laserstrahl mit einer stark vergrößernden Linse auf die Oberfläche fokussiert werden. Wegen der kleinen Schärfentiefe einer solchen Linse muss der Abstand zur Oberfläche genau eingehalten werden. Zur Unterdrückung von Störeinflüssen wie der ortsabhängigen Reflektivität der vermessenen Oberfläche und zur Extraktion der absoluten Schwingungsamplitude benutzen wir einen homodynen Aufbau mit zusätzlicher Pfadlängenmodulation. Die Messempfindlichkeit wurde dabei durch die Quadraturinterferometrie, das heißt die zeitsynchrone Erfassung der Intensitäten durch zwei Fotodioden, verbessert. Wir zeigen außerdem einen Signalverarbeitungsalgorithmus, der zur Regelung des Abstands zwischen Linse und Messoberfläche benutzt werden kann. Dies gewährleistet, dass der Laserstrahl optimal auf die Oberfläche fokussiert wird und führt zu einem insgesamt hohen Signal-zu-Rausch-Verhältnis.

Abstract

Surface vibrations with small amplitudes are often measured by interferometric techniques. For a good lateral resolution, the laser beam has to be focused on the surface through a high- magnification lens. Owing to the small depth of focus of this lens, its distance to the surface has to be controlled both accurately and precisely. In order to eliminate effects of influencing quantities such as the position-dependent surface reflectivity of the device under test, and to extract the absolute vibration amplitude, we use a homodyne setup with additional path length modulation. Its sensitivity is increased by quadrature interferometry, i. e., the synchronous measurement of the intensities detected by two photodiodes. We also present a signal processing technique for controling the distance between lens and surface. This ensures that the laser beam stays focused optimally onto the surface and results in a high overall signal-to-noise ratio.

Keywords: quadrature interferometry,; absolute amplitude measurement; autofocus; surface acoustic waves

About the article

* Correspondence address: Hochschule Furtwangen, Hochschulcampus Tuttlingen, Kronenstr. 16, 78532 Tuttlingen,


Published Online: 2010-09-09

Published in Print: 2010-09-01


Citation Information: tm - Technisches Messen Plattform für Methoden, Systeme und Anwendungen der Messtechnik, Volume 77, Issue 9, Pages 487–492, ISSN (Print) 0171-8096, DOI: https://doi.org/10.1524/teme.2010.0031.