Skip to content
BY-NC-ND 3.0 license Open Access Published by De Gruyter June 2, 2014

Eine Bleidioxid-Bezugselektrode /A Lead Dioxide Reference Electrode

  • Dietrich Wabner , Fritz Hindelang and Rainer Huss

Abstract

For research work in nitric acid and during the deposition of lead dioxide from nitric baths a reference electrode has proven its value, which consists of a lead dioxide layer on a titanium carrier. Its potential against n.h.e. lies at 1.455 + 0.002 V in 1 N Pb(NO3)2 + 0.1 N HNO3 at 295 K. This space-saving electrode can be used in the same electrolyte. It is stable against temperature variations and electronic control currents.

Received: 1978-7-24
Published Online: 2014-6-2
Published in Print: 1978-11-1

© 1946 – 2014: Verlag der Zeitschrift für Naturforschung

This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.

Downloaded on 28.3.2024 from https://www.degruyter.com/document/doi/10.1515/znb-1978-1133/html